CHARGING INSTRUCTIONS
Use caution when operating or servicing the PowerClean Max. NEVER INHALE CHEMICAL FUMES. Wear safety glasses and gloves
when using the feeder. Always follow your chemical manufacturer's guidelines for chemical use.
1. Shut off pump and close the control valve. Wait one minute. If installed below water level, close any in-line valves to prevent
back flow before the vent valve. Next, open the lid vent valve, then open the feeder bottom drain valve. Drain water into a plastic
container and pour into the pool.
2. Close the drain valve. Lift the lock spring and unscrew the lid lock ring. Remove feeder lid and fill with the appropriate chlorine
or bromine tablets.
3. Clean and lubricate the O-ring, then replace the lid. Only use silicone lubricant. Press the lid into position, then close the vent
valve. Tighten the lock ring until the o-ring contacts the body, then turn until the lock spring snaps into the next notch in the body.
There are four notches located on the upper flnage of the body. Never force the lock ring past the lock spring.
4. Open any in-line valves, and turn on pump/timer. Adjust the control valve to the proper setting.
IF ISOLATION VALVES ARE USED, you must open them before start-up. Always keep the return line valves open to prevent gas or
pressure build-up, except when opening or servicing the feeder. Close the control valve if adding chemicals to the pool,
vacuuming, backwashing or maintaining your filter.
WINTERIZING
During freezing temperature seasons, drain all water from the feeder body. Carefully remove undissolved tables using safety
gloves. Clean the feeder body with water, replacing the lid when complete. Leave the vent valve open slightly, and keep the feeder
covered all winter season.
1) 25280-615-500
2) 25280-615-106
3) N/A
4) N/A
5) 25280-6xx-100
6) 25280-615-104
7) 25280-615-200
8) 27313-010-100
9) 25203-453-925
10) 25280-615-300
11) 25280-615-400
OPTIONAL EQUIPMENT (not pictured)
25830-350-000
1.5" Corrosion Resistant Check Valve
25830-400-000
2" Corrosion Resistant Check Valve
25280-615-600
Flow Meter Assembly
MODEL
CAPACITY
25280-615-000
15lb
25280-630-000
30lb
25280-640-000
40lb
CUSTOM MOLDED PRODUCTS | 36 HERRING ROAD, NEWNAN, GA 30265 | WWW.C-M-P.COM
0519ab
Lid Assy w/ o-ring & air relief
Screen
O-ring
Check Ball
Body w/ Stand
Plug
Union
Threaded Coupling
Gasket
Flow Control Valve
Drain Valve

Publicité

loading

Ce manuel est également adapté pour:

25280-615-00025280-630-00025280-640-000