3.Open the battery cover of the remote control, install 2 "AAA" batteries
and activate the remote control.
4.Point the remote control directly at the control buttons of the log set and
use the buttons to operate the log set.
CARE AND MAINTENANCE
Before attempting ANY maintenance:
1.Turn off power to the unit.
2.Unplug the power cord from outlet.
3.Let log set cool if it has been operating.
Maintenance of Motors:
Always disconnect the appliance from the main power supply and
allow it to cool before any servicing operation.
The motors used on the fan heater and flame blower are pre-lubricated for
extended bearing life and require no further lubrication. However, periodic
cleaning/vacuuming of the appliance around the air intake and exhaust, as
well as the fan heater is recommended. For heavy or continuous use,
periodic cleaning must be done more frequently. lf the heater blows
alternating cold and warm air, check the fan for free movement and for
debris restricting air flow. lf the fan does not move freely, the unit must be
turned off and the fan replaced immediately in order to prevent further
damage to the unit.
Cleaning:
Cleaning of the log set is to be done only with a vacuum cleaner or by
using a soft cloth, slightly
dampened in water (if needed, a small amount of dish soap can be added
to the water) and dried
using a clean, dry soft cloth. DO NOT use any abrasive household
cleaners as these products will
damage the unit.
- 10 -