The manufacturer declines any liability should the safety measures not be observed.
Protect your appliance against atmospheric effects. Do not expose it to sun, rain, snow,
etc.
Warnings
Prior to installation, ensure that the local distribution conditions (nature of the gas and
gas pressure) and the adjustment of the appliance are compatible.
This appliance is not connected to a combustion products evacuation device. It shall be
installed and connected in accordance with current installation regulations. Particular
attention shall be given to the relevant requirements regarding ventilation.
Instructions for the installer
Overall Dimensions
Width:
600mm
Depth: 510mm
Cut out dimensions
The dimensions of the cut out are given in the diagram.
Dimensions are given in mm.
Appliance Class: 3
Burner technical data
THERMAL POWER (kW):
INJECTOR DIAMETER (mm):
THERMAL POWER (kW):
FLOW RATE (g/h):
INJECTOR DIAMETER (mm):
Natural gas category: I2H(20) / I2E+
LPG (Liquefied Petroleum Gas) category:
30
560
BURNER:
I3+ 28 30/37
Cut Out Dimensions
Width: 560mm
Depth: 480mm
Rapid
Semi rapid
(large)
(medium)
3.0
1.75
1.30
1.00
3.0
1.75
219
127
0.87
0.66
6
Auxiliary
(small)
1.0
0.78
1.0
73
0.50

Publicité