Troubleshooting - Reddyheater Rfg40V Mode D'emploi

Table des Matières

TROUBLESHOOTING:

PROBLEM
1. Control   d ial   i s   o ff   a nd   u nit   i s
clicking/4cking
2. The   u nit   i s   4 cking/clicking  
while   t he   h eater   i s   l it.
3. Fan   d oes   n ot   t urn   w hen
electrical   c onnec4on   i s   m ade.
4. Heater   w ill   n ot   fi re.
5. Heater   q uits   w hile
running.
Always be sure to follow proper maintenance procedures, by cleaning the heater once per
month during regular usage, and check spark gap at least once per season.
FOR TECHNICAL ASSISTANCE SEE YOUR LOCAL RETAILER OR CONTACT US AT:
PHONE: 800-776-9425
EMAIL: support@worldmkting.com or
info@worldmkting.com www.worldmkting.com
11
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING
POSSIBLE   C AUSE
1. This   h eater   u ses   a   c on4nuous   s park
igni4on   s ystem.   T his   u nit   w ill   c on4nue
to   m ake   a   c licking/4cking   s ound   a t   a ll
4mes   b efore   i gni4on,   a Aer   i gni4on
and   d uring   o pera4on,   r egardless   o f
valve   k nob   p osi4oning.
1. This   h eater   u ses   a   c on4nuous   s park
igni4on   s ystem.   T his   u nit   w ill   c on4nue
to   m ake   a   c licking/4cking   s ound   a t   a ll
4mes   b efore   i gni4on,   a Aer   i gni4on
and   d uring   o pera4on,   r egardless   o f
valve   k nob   p osi4oning.
1. No   e lectric   p ower   t o   h eater.
2. Fan   b lade   c ontacts   i nside   o f   h eater   h ousing.
3. Fan   b lade(s)   b ent
4. Fan   m otor   d efec4ve.
1. No   s park   a t   i gnitor.
2. Improper   s park   g ap.
3. Bad   e lectrode.
1. Internal   t emperature   t oo   h igh   c ausing   l imit  
switch   t o   s hut   d own   o pera4on.
2. Damaged   C ontrol   V alve.
3. Dust   o r   d ebris   b uild-­‐up   i nside   o f   h eater.
CORRECTIVE   A CTION
1. No   c orrec4ve   a c4on   i s   n eeded.
1. No   c orrec4ve   a c4on   i s   n eeded.
1. Check   c urrent   t o   e lectric   o utlet.   I f   v oltage   i s   c orrect,
check   p ower   c ord   a nd   e xtension   c ord   f or
2. Be   s ure   t hat   h ousing   i s   n ot   d amaged.   M ake   s ure
there   a re   n o   o bstruc4ons   t o   t he   f an.
3. Straighten   b lade(s)   t o   m atch   o thers.
4. Replace   m otor.
1. Check   i gnitor   w ire.   R e-­‐aQach   o r   4 ghten   i f   l oose.
Check   S park   m odule.   R eplace   i f   n ecessary.
2. Set   g ap   ( See   s pecifica4ons   f or   g ap).  
3. Replace   S park   P lug.
1. If   t he   h eaters   o utput   i s   r estricted,   i nternal   t emperature
becomes   t oo   h igh.   M ove   h eater   a way   f rom
any   o bstruc4ons.
2. Replace   C ontrol   V alve.
3. Clean   i nside   o f   h eater.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rfg50vRfg60vRfg100vRfg125vRfg150v

Table des Matières