  • Page 3 Declaration of Conformity Issue Date: December 2018 Model #/s: Model ATH Series Type of Equipment: RF Broadband Antennas Function: Designed to be used in a RF immunity test system or for research. The equipment described above is declared to be in conformity with the following applicable national and international standards.
  • Page 5 INSTRUCTIONS FOR SAFE OPERATION Observe the following safety guidelines to help ensure your own any vents or air intakes. Restricting airflow can result in damage personal safety and to help protect your equipment and working to the equipment, intermittent shut-downs or safety hazards. environment from potential damage.
  • Page 6 INSTRUCTIONS FOR SAFE OPERATION HAZARDOUS RF VOLTAGES RF ANTENNAS The RF voltages on the center pin of an RF output connector can be This equipment (antenna or antenna assembly) may be heavy, • hazardous. The RF output connector should be connected requiring two persons to lift.
  • Page 7 HINWEISE FÜR DEN SICHEREN GEBRAUCH Halten Sie einen Mindestabstand von 10,2 cm (4 in) auf allen belüfteten • Seiten des Geräts ein, um eine ausreichende Luftzirkulation zu Bitte beachten Sie die folgenden Hinweise zum Schutz Ihrer persönlichen gewährleisten. Beinträchtigen Sie den Luftstrom des Geräts nicht, indem Sicherheit und um Ihre Ausrüstung und Ihren Arbeitsplatz vor möglichen Sie Lüftungsöffnungen oder den Lufteinlass blockieren.
  • Page 8 HINWEISE FÜR DEN SICHEREN GEBRAUCH GEFÄHRLICHE HF-SPANNUNGEN HF-ANTENNEN Die HF-Spannungen am mittleren Pin eines HF-Ausgangsanschlusses können Die Ausrüstung (Antenne oder Antennenmontage) ist mitunter schwer. • gefährlich sein. Der HF-Ausgangsanschluss sollte an eine Last Die Montage erfordert daher oft zwei Personen. Folgen Sie allen in angeschlossen werden, bevor das Gerät ans Stromnetz diesem Dokument angegebenen Anweisungen zur Anbringung.
  • Page 9 INSTRUCTIONS POUR UN FONCTIONNEMENT EN TOUTE SÉCURITÉ Respectez les consignes de sécurité suivantes pour veiller à votre N’utilisez pas l’équipement dans un environnement humide, par • propre sécurité et vous aider à protéger votre équipement et votre exemple près d’un lavabo, ou dans un sous-sol humide. milieu de travail de dommages potentiels.
  • Page 10 INSTRUCTIONS POUR UN FONCTIONNEMENT EN TOUTE SÉCURITÉ TENSIONS RF DANGEREUSES • Assurez-vous que les connecteurs sont appropriés pour l’utilisation prévue. Les connecteurs sont indiqués dans le manuel Les tensions RF sur la broche centrale d’un connecteur de sortie RF d’utilisation et la fiche signalétique du produit. peuvent être dangereuses.
  • Page 11 INSTRUCTIES VOOR VEILIG GEBRUIK Neem de volgende veiligheidsrichtlijnen in acht om uw persoonlijke Laat een vrije ruimte van 10,2 cm (4 inch) aan alle geventileerde • veiligheid te helpen waarborgen en uw apparaat en werkomgeving zijden van het apparaat om de luchtstroom die nodig is voor goede tegen mogelijke schade te beschermen.
  • Page 12 INSTRUCTIES VOOR VEILIG GEBRUIK GEVAARLIJKE RF-SPANNINGEN RF-ANTENNES De RF-spanning op de middelste pin van een RF-outputconnector kan Dit apparaat (antenne of antenne-set) kan zwaar zijn, waardoor er • gevaarlijk zijn. De RF-uitgangsconnector moet op een twee personen nodig zijn om het op te tillen. Wees voorzichtig bij massa worden aangesloten voordat er wisselstroom op het het installeren of verwijderen van het apparaat.
  • Page 13 CONTENTS CONTENTS........................i MODEL ATH6G18 ANTENNA ..............1 Description ......................1 Assembly and Mounting Instructions ..............1 Extended Operating Band .................. 1 Dimensions ......................2 Specifications ....................2 RADIATION PATTERNS ................3 6 GHz, E-Plane ....................3 6 GHz, H-Plane....................3 8 GHz, E-Plane ....................
  • Page 15 ASSEMBLY AND MOUNTING INSTRUCTIONS The ATH6G18 comes ready to use. The ATH6G18 can be tripod-mounted using the ¼-20 threaded hole of the furnished mounting pad. The mounting pad can be positioned on the horn’s narrow wall or broad wall by removing the attachment screw.
  • Page 16 Model ATH6G18 DIMENSIONS Figure 1-1. Dimensions SPECIFICATIONS See the AR RF/Microwave Instrumentation data sheet at the end of this section for detailed specifications. Rev A...
  • Page 17 Graphs Features Model ATH6G18 is a wide-band, high-gain mi- ATH6G18 crowave horn antenna with WRD-650 double- ridged waveguide input. It operates down to 6.0 GHz, extending the conventional WRD-650 op-  High Gain Horn erating band. Model ATH6G18 is capable of...
  • Page 18 Graphs Page 2 ATH6G18  High Gain Horn Antenna  WRD-650 Wave- guide Input  6 GHz–18 GHz...
  • Page 19 Graphs Page 3 ATH6G18  High Gain Horn Antenna  WRD-650 Wave- guide Input  6 GHz–18 GHz To order AR Products, call 215.723.8181. For an applications engineer call:800.933.8181. Direct to Service call: 215.723.0275 or email: service@arworld.us For Faxing Orders:866.859.0582 (Orders Only Please) info@arworld.us...
  • Page 21 2. RADIATION PATTERNS Computed far-field E-Plane and H-Plane radiation patterns are shown on the following pages. These are computed in a fully anechoic environment (no conductive ground plane effects). 6 GHZ, E-PLANE 6 GHz, E-Plane Degrees 6 GHZ, H-PLANE 6 GHz, H-Plane Degrees Rev A...
  • Page 22 Model ATH6G18 8 GHZ, E-PLANE 8 GHz, E-Plane Degrees 8 GHZ, H-PLANE 8 GHz, H-Plane Degrees Rev A...
  • Page 23 Model ATH6G18 10 GHZ, E-PLANE 10 GHz. E-Plane Degrees 10 GHZ, H-PLANE 10 GHz, H-Plane Degrees Rev A...
  • Page 24 Model ATH6G18 12 GHZ, E-PLANE 12 GHz, E-Plane Degrees 12 GHZ, H-PLANE 12 GHz, H-Plane Degrees Rev A...
  • Page 25 Model ATH6G18 14 GHZ, E-PLANE 14 GHz, E-Plane Degrees 2.10 14 GHZ, H-PLANE 14 GHz, H-Plane Degrees Rev A...
  • Page 26 Model ATH6G18 2.11 16 GHZ, E-PLANE 16 GHz, E-Plane Degrees 2.12 16 GHZ, H-PLANE 16 GHz, H-Plane Degrees Rev A...
  • Page 27 Model ATH6G18 2.13 18 GHZ, E-PLANE 18 GHz, E-Plane Degrees 2.14 18 GHZ, H-PLANE 18 GHz, H-Plane Degrees Rev A...
  • Page 28 Model ATH6G18 Rev A...
  • Page 29 3. POLARIZATION OF HORN ANTENNAS Rev A...
  • Page 30 Model ATH6G18 Rev A...
  • Page 31 WARRANTIES: LIMITATION OF LIABILITY Seller warrants (i) that seller has title to the goods sold and (ii) that Amplifiers (all parts excluding traveling wave and vacuum tubes), Antennas, field monitors, field probes, field analyzers, field analyzer processor units, system controllers, system interlock, power meters, leak detectors, RF conducted probes, RF conducted clamps, Multi-tone, EMI receiver systems, RF down converters, RF conducted immunity systems, conducted immunity accessories, radiated immunity test systems, safety meters, safety sensor heads, tripods, directional couplers, waveguide adapters, termination loads, load attenuators, impedance stabilization networks, and coaxial cables...