Table of Contents/Table des matières............................................................................. 2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
LI31GA/W10526059C

Publicité

loading

Sommaire des Matières pour Amana UXW6530BS

  • Page 1 All manuals and user guides at all-guides.com 30" AND 36" (76.2 AND 91.4 CM) WALL-MOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance, parts, accessories or service, call: 1-800-253-1301 or visit our website at www.whirlpool.com In Canada, call 1-800-807-6777 or visit our website at www.whirlpool.ca HOTTE DE CUISINIÈRE À...
  • Page 2 All manuals and user guides at all-guides.com TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY ..............2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE........15 INSTALLATION REQUIREMENTS ..........4 EXIGENCES D'INSTALLATION ...........17 Tools and Parts ................4 Outils et pièces................17 Location Requirements..............4 Exigences d’emplacement............17 Venting Requirements..............5 Exigences concernant l’évacuation ...........18 Electrical Requirements ...............6...
  • Page 3 All manuals and user guides at all-guides.com IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may Use this unit only in the manner intended by the ignite.
  • Page 4 All manuals and user guides at all-guides.com INSTALLATION REQUIREMENTS 2 - 8 x 40 mm wall anchors Tools and Parts 4 - 10 x 50 mm wall anchors Gather the required tools and parts before starting installation. ®† T10 Torx adapter Read and follow the instructions provided with any tools listed ®†...
  • Page 5 All manuals and user guides at all-guides.com The chimneys can be adjusted for different ceiling heights. See the following chart. Vented Installations Min. ceiling height Max. ceiling height **27¹⁄₈" (68.9 cm) min. 7' 4" (2.23 m) 9' 5" (2.87 m) Electric cooking **41¹⁄₈"...
  • Page 6 All manuals and user guides at all-guides.com Example vent system Venting Methods Wall cap 90 elbow 6 ft (1.8 m) This canopy hood is factory set for venting through the roof or wall. A 6" (15.2 cm) round vent system is needed for installation (not included).
  • Page 7 All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS Prepare Location 5. Drill ³⁄₁₆" (4.8 mm) pilot holes at all locations where screws are It is recommended that the vent system be installed before hood is installed. being installed into wood. 6.
  • Page 8 All manuals and user guides at all-guides.com For non-vented (recirculating) installation only: Install Range Hood 1. Assemble the air deflector with the duct cover bracket using 4 - 4 x 8 mm screws. 1. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood.
  • Page 9 All manuals and user guides at all-guides.com 5. Use UL listed wire connectors and connect black wires (C) together. Make Electrical Connection 6. Use UL listed wire connectors and connect white wires (E) together. WARNING WARNING Electrical Shock Hazard Disconnect power before servicing. Electrical Shock Hazard Replace all parts and panels before operating.
  • Page 10 All manuals and user guides at all-guides.com Secure the bottom of the duct with 2 - 4 x 8 mm screws. Complete Installation 1. For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. See the “Range Hood Care”...
  • Page 11 All manuals and user guides at all-guides.com RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently 4. Bend spring clips back into place to secure the charcoal filter according to the following instructions. Replace grease filters to the metal filter. before operating hood.
  • Page 12 All manuals and user guides at all-guides.com WIRING DIAGRAM Switch Operation Position Function No connection Brown - Yellow Lamps (L - LA) Brown - White Low Speed (L - 1) Brown - Red Med Speed (L - 2) Brown - Black High Speed (L - 3) Motor Resistance...
  • Page 13 All manuals and user guides at all-guides.com ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your Accessories appliance. This information will help us to better respond to your request.
  • Page 14 All manuals and user guides at all-guides.com WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship.
  • Page 15 All manuals and user guides at all-guides.com SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité...
  • Page 16 All manuals and user guides at all-guides.com IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS Ne jamais laisser un élément de surface fonctionner à...
  • Page 17 All manuals and user guides at all-guides.com EXIGENCES D'INSTALLATION 4 - pièces d'ancrage mural de 10 x 50 mm Outils et pièces Adaptateur T10 Torx ®† Rassembler les outils et pièces nécessaires avant d’entreprendre Adaptateur T20 ®† Torx ® l’installation. Lire et observer les instructions fournies avec chacun des outils de la liste ci-dessous.
  • Page 18 All manuals and user guides at all-guides.com Installations sans décharge à l’extérieur (recyclage) Hauteur minimale Hauteur maximale sous plafond sous plafond 7' 4" (2,23 m) 9' 9" (2,97 m) Surface de cuisson **27¹⁄₈" (68,9 cm) min. électrique **41¹⁄₈" (104,5 cm) max. Surface de cuisson à...
  • Page 19 All manuals and user guides at all-guides.com Exemple de circuit d'évacuation Méthodes d’évacuation Bouche de décharge murale Coude à 90˚ Cette hotte a été configurée à l'usine pour la décharge de l'air 6 pi (1,8 m) aspiré à travers le toit ou à travers un mur. Un circuit d'évacuation en conduit rond de 6"...
  • Page 20 All manuals and user guides at all-guides.com INSTRUCTIONS D’INSTALLATION Préparation de l’emplacement Il est recommandé d’installer le circuit d’évacuation avant de 4. À l’aide du gabarit, marquer sur le mur le centre des attaches. procéder à l’installation de la hotte. IMPORTANT : Toutes les vis doivent être vissées dans du bois.
  • Page 21 All manuals and user guides at all-guides.com Installations sans décharge à l'extérieur (recyclage) uniquement : Installation de la hotte 1. Fixer le déflecteur à la bride de cache-conduit à l’aide de 1. À deux personnes au moins, suspendre la hotte aux 4 vis de 4 x 8 mm.
  • Page 22 All manuals and user guides at all-guides.com Raccordement électrique 4. Acheminer le cordon d'alimentation du domicile à travers le AVERTISSEMENT serre-câble, dans le boîtier de connexion. Risque de choc électrique Déconnecter la source de courant électrique avant l'entretien. Replacer pièces et panneaux avant de faire la remise en marche.
  • Page 23 All manuals and user guides at all-guides.com Installation des cache-conduits UTILISATION DE LA HOTTE En cas d’utilisation des sections supérieure et inférieure du cache-conduit, pousser la section inférieure vers le bas, sur la La hotte de cuisinière est conçue pour extraire fumée, vapeurs de hotte et soulever la section supérieure vers le plafond puis cuisson et odeurs de la zone de la table de cuisson.
  • Page 24 All manuals and user guides at all-guides.com ENTRETIEN DE LA HOTTE Nettoyage IMPORTANT : Nettoyer fréquemment la hotte et les filtres à 4. Replier les attaches à ressort pour les remettre en place afin graisse en suivant les instructions suivantes. Réinstaller les filtres de fixer le filtre à...
  • Page 25 All manuals and user guides at all-guides.com SCHÉMA DE CÂBLAGE Terre Fonctionnement du JA/VE commutateur Position Connexion Pas de connexion Off (arrêt) Marron - Jaune Lampes (L - LA) Marron - Blanc Vitesse basse (L - 1) Marron - Rouge JA/VE Vitesse moyenne (L - 2)
  • Page 26 All manuals and user guides at all-guides.com ASSISTANCE OU SERVICE Lors d’un appel pour assistance ou service, veuillez connaître la Pour plus d’assistance date d’achat, le numéro de modèle et le numéro de série Si vous avez besoin de plus d’assistance, vous pouvez complets de l’appareil.
  • Page 27 All manuals and user guides at all-guides.com GARANTIE DES GROS APPAREILS MÉNAGERS WHIRLPOOL CORPORATION GARANTIE LIMITÉE Pendant un an à compter de la date d'achat, lorsque ce gros appareil ménager est utilisé et entretenu conformément aux instructions jointes à ou fournies avec le produit, Whirlpool Corporation ou Whirlpool Canada LP (ci-après désignées “Whirlpool”) paiera pour les pièces spécifiées par l'usine et la main-d'œuvre pour corriger les vices de matériaux ou de fabrication.
  • Page 28 All manuals and user guides at all-guides.com W10526059C © 2012 Whirlpool Corporation. 12/12 All rights reserved. Used under license in Canada. Printed in Mexico Tous droits réservés. Utilisée sous licence au Canada. Imprimé au Mexique...