Installation Methods; Wiring Diagram - Vevor Amx-Fag10 Mode D'emploi

Table des Matières
Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
AMX-FAG12
Shutter
Exhaust
AMX-FAG16
Fan
AMX-FAG16
※Performance value is the average value of our test result.
※Applicable area calculation is based on essential ventilation of 5-
10 times /hour in

Installation Methods

1. Firstly, make an installing hole in the wall. For the hole size,
please refer to the attached list.
2. Fix the fan on the wall with the bolt.( Picture 1 )
3. Refer to the electrical diagram, connect the fan to AC electricity
of 120V/60Hz, then use the single-phase switch as the fan control
switch to control the fan's start and stop. (Picture 2)
Series
Shutter
Exhaust
Fan

WIRING DIAGRAM

1700
3400
5650
a normal
living room.
AMX-FAG10
AMX-FAG12
AMX-FAG16
AMX-FAG24
<60
<65
<70
Model
(No.)
Outdoor
Indoor
Fan
Bolt
Picture 1
- 6 -
3.05
55~110
5.15
110~220
10
180~350
Hole Size
(W*H)
275*265MM
319*311MM
415*415MM
620*620MM
Table des Matières