12 MAINTENANCE
Default settings:
LEDs status
-
-
Buzzer status
Failure
Permanent alarm
No triggering of the
intrusion alarm
Anti-masking alarm in
permanent alarm
Permanente tamper
alarm
PIRAMID is not found
in the MAXIBUS
UNIVERSAL network
The smartphone
application cannot
detect the PIRAMID.
: disable
(see §8.2 or §9.3 for led settings)
: enable
(see §8.2 or §9.3 for buzzer settings)
Probable causes
- "Test Mode" switch in the ON
position.
Incorrect voltage (<10V)
-
-
The relays are disabled.
Passage beyond the distance
-
set on the code selector.
The relays are disabled.
-
-
The anti-masking alarm is
disabled.
Tamper switches are in up.
-
- RS485 bus cable error.
- Product connected to the
application in BLE.
- The PIRAMID BLE connection
is not activated.
-
Turn the "Test Mode" switch to the
OFF position.
Check the power supply.
-
-
Enable relays via the MAXIBUS
UNIVERSAL (see §9.3) or the
application (see §8.2)
Change the distance set on the
-
code selector.
Enable relays via the MAXIBUS
-
UNIVERSAL (see §9.3) or
application (see §8.2)
-
Enable the anti-masking alarm
(see §9.3 or §8.2)
If the tamper is to be used in a local
-
connection, wire the terminals 13,
14, 15.
If the tamper is to be used in a
-
network connection, turn the
switches to the bottom.
-
Check the cabling the presence of
end-of-line resistors. (see §9.1).
Disconnect from the application
-
-
Press on the tamper switch for at
least 2 seconds, then release.
(see §8)
Check that the tamper switches are
-
towards the bottom. (see §8)
- 62 -