Caractéristiques techniques IR420-D4..
Coordination de l´isolement selon CEI 60664-1/CEI 60664-3
Tension assignée...................................................................................................................... 250 V
Qualité diélectrique / degré de pollution ........................................................................... 4 kV / III
Séparation sûre (isolation renforcée) entre:
............................................................... (A1, A2) - (L1, L2, E, KE, T/R) - (11-12-14) - (21-22-24)
Essai diélectrique selon CEI 61010-1 .................................................................................. 2,21 kV
Tension d´alimentation
IR420-D4-1:
Tension d´alimentation U
.................................................................. AC 16...72 V / DC 9,6...94 V
s
Gamme de fréquences U
...................................................................................... 42...460 Hz / DC
s
IR420-D4-2:
Tension d´alimentation U
................................................................................... AC/DC 70...300 V
s
Gamme de fréquences U
........................................................................................ 42...460 Hz, DC
s
Consommation propre .........................................................................................................
Réseau IT surveillé
Tension réseau U
........................................................................................................ AC 0... 300 V
n
Fréquence nominale f
.................................................................................................. 42...460 Hz
n
Valeurs de seuil
Valeur de seuil R
(ALARM 1) ..................................................................................... 1...200 kΩ
an1
Valeur de seuil R
(ALARM 2) ..................................................................................... 1...200 kΩ
an2
Fonction Preset :
U
72 V: R
(ALARM 1)/ R
(ALARM 2) ........................................................ 20 kΩ / 10 kΩ
n
an1
an2
>
U
72 V: R
(ALARM 1)/ R
(ALARM 2) ........................................................ 46 kΩ / 23 kΩ
n
an1
an2
Tolérance du seuil (1...5 kΩ) / (5...200 kΩ) ...................................................
Hystérèse (1...5 kΩ) / (5...200 kΩ) .................................................................. +1 kΩ / +25 %
Temps de réponse
Temps de réponse t
pour R
= 0,5 x R
an
F
an
Temporisation de démarrage t ............................................................................................ 0...10 s
Durée de fermeture t
........................................................................................................ 0...99 s
on
Circuit de mesure
Tension de mesure U
............................................................................................................
m
Courant de mesure I
(pour R
= 0Ω)..........................................................................
m
F
Résistance interne DC R
.....................................................................................................
i
Impédance Z
pour 50 Hz...................................................................................................
i
Tension DC maxi. étrangère U
....................................................................................
fg
Capacité de fuite C
..............................................................................................................
e
Affichage, mémoire
Affichage....................................................................... écran LC, multi fonctions, non rétroéclairé
Zone d´affichage, valeur mesurée ............................................................................. 1 kΩ...1 MΩ
Erreur maximale de fonctionnement (1...5 kΩ) .............................................................
Erreur maximale de fonctionnement (5 kΩ...1 MΩ) ........................................................
Mot de passe ................................................................................................................. off / 0...999
Mémorisation des défauts (relais d´alarme) ....................................................................... on / off
Entrées
Longueur du câble touche Test- / Reset externe .................................................................
Nombre et type
Nombre .......................................................................................................... 2 (inverseurs K1, K2)
Mode de travail ................................................................... courant de repos / courant de travail
Durée de vie électrique sous des conditions assignées de fonctionnement.... 10000 manoeuvres
Données des contacts selon CEI 60947-5-1:
Tension de fonctionnement nominale AC .......................................................... 230 V....... 230 V
Catégorie d´utilisation AC ................................................................................... AC 13....... AC 14
Courant de fonctionnement nominal AC ................................................................ 5 A............ 3 A
Tension de fonctionnement nominale DC ....................................... 220 V ....... 110 V.......... 24 V
Catégorie d´utlisation DC ................................................................. DC 12....... DC 12....... DC 12
Courant de fonctionnement nominal DC ........................................ 0,1 A ........ 0,2 A............ 1 A
Courant minimal ..................................................................................... 1 mA pour AC/DC ≥ 10 V
IR420-D4_D00037_00_M_FREN / 07.2013
0,5 kΩ /
±
= 1 μF.......................................................
et C
e
Technical data IR420-D4..
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated insulation voltage........................................................................................................... 250 V
Rated impulse voltage / Pollution degree........................................................................ 2.5 kV / III
Protective separation (reinforced insulation) between:
.............................................................. (A1, A2) - (L1, L2, E, KE, T/R) - (11, 12, 14) - (21, 22, 24)
Voltage test acc. IEC 61010-1 .............................................................................................. 2.21 kV
Supply voltage
IR420-D4-1:
Supply voltage U
................................................................................ AC 16...72 V / DC 9.6...94 V
s
Frequency range U
s
IR420-D4-2:
Supply voltage U
................................................................................................. AC/DC 70...300 V
s
Frequency range U
s
Power consumption .............................................................................................................. ≤ 4 VA
4 VA
IT System being monitored
Nominal system voltage U
Nominal frequency f
n
Response values
Response value R
an1
Response value R
an1
Preset function:
U
72 V: R
(ALARM 1)/ R
n
an1
>
U
72 V: R
(ALARM 1)/ R
n
an1
±
15 %
Operating error (1...5 kΩ) / (5...200 kΩ)
Hysteresis (1...5 kΩ) / (5...200 kΩ) ....................................................................+1 kΩ / +25 %
Time response
1 s
Response time t
at R
an
Starting delay t ...................................................................................................................... 0...10 s
Response delay t
................................................................................................................ 0...99 s
on
Measuring circuit
±
12 V
Measuring voltage U
200 μA
Measuring current I
m
62 kΩ
Internal d.c. resistance R
60 kΩ
Internal impedance Z
DC 300 V
Admissible extraneous d.c. voltage U
20 μF
System leakage capacitance C
Displays, memory
Display ..................................................................... LC display, multi-functional, non-illuminated
Display range, measuring value ................................................................................ 1 kΩ...1 MΩ
±
0,5 kΩ
Operating error (1...5 kΩ) ................................................................................................
±
15 %
Percentage operating error (5 kΩ...1 MΩ) ........................................................................
Password ........................................................................................................................ off / 0...999
Fault memory (alarm relay) ................................................................................................. on / off
Inputs
≤ 10 m
Cable length external test / reset button..............................................................................
Switching elements
Number of....................................................................................... 2 (changeover contacts K1, K2)
Operating principle....................................................................... (N/O operation) (N/C operation)
Electrical endurance ............................................................................ 10000 switching operations
Contact data according IEC 60947-5-1
Rated operational voltage AC ............................................................................... 230 V ....... 230 V
Utilization category AC ........................................................................................ AC 13 ....... AC 14
Rated operational current AC .................................................................................. 5 A ........... 3 A
Rated operational voltage DC ............................................................ 220 V....... 110 V ......... 24 V
Utilization category DC ...................................................................... DC 12........DC 12 ....... DC 12
Rated operational current DC ............................................................ 0.1 A........ 0.2 A ........... 1 A
Minimum current ..........................................................................................1 mA at AC/DC ≥ 10 V
ISOMETER® IR420-D4
................................................................................................ 42...460 Hz / DC
................................................................................................. 42...460 Hz, DC
......................................................................................... AC 0... 300 V
n
..................................................................................................... 42...460 Hz
(ALARM 1).............................................................................. 1 kΩ...200 kΩ
(ALARM 2).............................................................................. 1 kΩ...200 kΩ
(ALARM 2) ........................................................ 20 kΩ / 10 kΩ
an2
(ALARM 2) ........................................................ 46 kΩ / 23 kΩ
an2
........................................... ±
= 1 μF ............................................................... ≤ 1 s
= 0,5 x R
and C
F
an
e
............................................................................................................
m
(R
= 0Ω) ..................................................................................
F
....................................................................................................
i
(50 Hz) ...........................................................................................
i
.........................................................................
fg
............................................................................................
e
0.5 kΩ /
±
15 %
±
12 V
200 μA
62 kΩ
60 kΩ
DC 300 V
20 μF
±
0.5 kΩ
±
15 %
10 m
7