INSTALLATION INSTRUCTIONS - RFL2 & RFL3 LED FLOOD
Installing the Photocontrol (See Fig. 4, 5, and 6)
•
Turn off power to electrical connections.
•
Wiring must be performed by a qualified electrician.
•
Remove Photocontrol from packaging along with hardware bag.
•
Rremove the four screws on the rear of the flood light.
•
Remove the front plate and drill an 11/16" (0.6875") diameter hole on the location provided (Item 1, Fig 2).
•
Mount the Photocontrol in the drilled hole.
•
Connect the Photocontrol as shown in Fig. 3A.
•
Reinstall the front plate with light engine and tighten the screws that were removed.
NOTES:
For replacement LED Assemblies and Drivers please contact Hubbell Lighting for any replacement parts.
Contact your local distributor or agent to confirm parts availability prior to ordering replacement parts.
93101893 Rev. A
701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000
SAVE THESE INSTRUCTIONS
PHOTOCONTROL
OPTION
LINE
BLACK (LINE)
COM
WHITE(NEUT)
GROUND
GREEN
GRD
Fig 3A: WIRING DIAGRAM FOR RFL2 & RFL3 FLOOD
FIGURE 2
RED (+)
DC
OUTPUT
BLACK (-)
DRIVER
DIMMING
AC
LEADS
INPUT
SHEET 2 OF 2
RED
BLACK
LED
BOARD
www.hubbelloutdoor.com