7.2 Maintenance
Regular inspection and servicing have a positive effect on the reliable
functioning of the product and should be carried out at least once a year.
Except for the necessary filter replacements, the product operates
maintenance-free.
Observe the warning notices for servicing and troubleshooting in the
"Safety" chapter.
7.2.1 Emptying the dust collection container
The dust collection container fill level must be checked at regular intervals.
The time period in which the dust collection bucket/disposal bag must be
changed depends on the type and quantity of use of the separated dust
particles. For this reason, we cannot state specific replacement intervals.
WARNING
Health hazards caused by welding fume particles
Inhalation of welding fume particles, especially welding fume particles
from welding processes on alloyed steels, can damage your health as
they are 'respirable'. Skin contact with welding fume particles can cause
skin irritation in sensitive individuals.
To avoid contact with and inhalation of these dust particles, wear
disposable overalls, protective goggles, gloves and a suitable Class FFP2
respiratory protection filter mask in accordance with EN 149.
When emptying the dust collection container, please proceed as follows:
1. Switch off the product using the I/O switch.
2. Wait 2 minutes for the dust particles to settle inside the filter section.
1502029-00
- 71 -
EN