Bull NovaScale R410B F2 Guide De Mise En Route page 17

Masquer les pouces Voir aussi pour NovaScale R410B F2:
Table des Matières
Les langues disponibles

Les langues disponibles

Physical
Height
Width
Depth
Weight (maximum configuration)
Environmental
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
All manuals and user guides at all-guides.com
4.24 cm (1.67 in)
43.4 cm (17.09 in)
39.37 cm (15.5 in)
8.058 kg (17.77 lb)
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
maximum operating temperature is derated
1ºF/550 ft.
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.26 Grms at 5–350 Hz for 15 min
1.87 Grms at 10–250 Hz for 15 min
Getting Started With Your System
For altitudes above 2950 feet, the
13