Instruction CF-RC Remote Controller
Alarm:
From this menu, you can switch the Buzzer of the Master Controller
(MC) On/O . The sound only occurs in case of an alarm, also indicated
by the red alarm LED on the Master Controller (see g. 3-
). In the
Alarm log, you can get speci c information about the error causing
the alarm and the time for its registration by the system. This Alarm log
saves the latest alarms for later access and easy system failure identi -
cation.
Start-up screen:
Here you can choose which room temperature you want displayed on
the start-up screen.
Service:
Here you can con gure all the outputs of the Master Controller (see g.
5 a) for either a oor or radiator heating system. With oor heating, you
can choose regulation by means of an On/O or a PWM (Pulse Width
Modulation) principle. Choosing a radiator system automatically sets
the regulation to PWM. Even a mixed system with oor and radiator
heating in separate rooms can be selected by setting the outputs of the
Master Controller individually for each room to either oor or radiator
heating.
Note: When the Master Controller is regulated by PWM, the cycle times are:
Floor heating: 2 hours
Radiator heating: 15 minutes.
VI.UH.M2.52
17
Produced by Danfoss Floor Heating Hydronics 09.2005