Télécharger Imprimer la page
LEGRAND adorne ARTR202 Notice D'installation
LEGRAND adorne ARTR202 Notice D'installation

LEGRAND adorne ARTR202 Notice D'installation

Prise inviolable à 2 modules, 20 a, 125 vca

Liens rapides

No: 340951 – 03/12 Rev. 1
Catalog Number(s) • Numéro(s) de catalogue • Número(s) de catálogo: ARTR202
Country of Origin: Made in China • Pays d'origine : Fabriqué en Chine • País de origen: Hecho en China
Ground Wire
Fil de terre
Cable a tierra
Ground Wire
Fil de terre
Cable a tierra
HOT
HOT
Split Circuit Tab
WHITE
Ecartez la languette du circuit
Lengüeta del circuito partida
1
WARNING
To prevent severe shock or electrocu-
tion, always disconnect power at the
service panel before beginning work.
AVERTISSEMENT
Pour éviter toute décharge grave
ou électrocution, éteignez toujours
l'alimentation au niveau du panneau
de service avant de travailler.
ADVERTENCIA
Para evitar electrocuciones o
descargas eléctricas graves,
desconecte siempre la alimentación
en el panel de servicio antes de
comenzar a trabajar.
When replacing existing outlets,
label wires before disconnecting.
disconnect old outlet.
lorsque vous remplacez des prises
existantes, étiquetez le câble avant
de débrancher.
débranchez l'ancienne
prise..
Al reemplazar los dispositivos
existentes, marque los cables antes
de desconectarlos.
desconecte el tomacorriente
viejo..
2
If necessary,cut wires and strip
insulation using stripping guide on
back of outlet.
si nécessaire, coupez les fils et
dénudez l'isolation à l'aide du guide
de dénudage au dos de la prise.
si es necesario, corte los cables
y pele el aislamiento con la guía
pelacables de la parte posterior del
tomacorriente.
3
WARNING
Failure to connect the
ground wire will result in an
unsafe installation that could
lead to personal injury.
AVERTISSEMENT
Ne pas raccorder le fil de
mise à la terre peut rendre
une installation dangereuse
pouvant occasionner des
blessures.
ADVERTENCIA
Si no conecta el cable de
tierra, se producirá una
instalación insegura y
podrían ocasionar lesiones
personales.
Frame
Cadre
Wall Plate
Bastidor
Plaque murale
Placa de pared
Outlet
Prise
Tomacorriente
Neutral (White), Neutre
Hot (Black), Actif
Ground (Bare), Fil de garde
Connect frame ground wire and
outlet ground wire to bare ground
wire in box. Fold ground wires into
back of box. Mount frame to wall
box with screws provided. Tighten
screws just enough to hold frame
in place. do Not over-tighten.
Raccordez le fil de garde du cadre
et le fil de garde de sortie au fil de
garde nu dans le boîtier. Pliez les
fils de mise à la terre et insérez-
les à l'arrière du boîtier. Montez le
cadre à la boîte murale avec les
vis fournies. serrez suffisamment
les vis pour maintenir le cadre en
place. Ne serrez Pas trop.
Conecte el conductor de tierra
del marco y el conductor de tierra
del tomacorriente al conductor de
tierra pelado en el interior de la
caja. Pliegue los cables a tierra en
la parte posterior de la caja. Monte
el bastidor a la caja de la pared
con los tornillos provistos. Ajuste
los tornillos lo suficiente como para
sostener el bastidor en el lugar.
No ajuste en exceso.
adorne
TM
Tamper-Resistant Outlet, 2-Module, 20A, 125 VAC
Prise inviolable à 2 modules, 20 A, 125 VCA
Tomacorriente a prueba de manipulación, módulo doble, 20 A, 125 VAC
Installation Instructions • Notice d'installation • Instrucciones de instalación
For more information and helpful
how-to videos, visit
www.adornemyhome.com/install.
INstallatIoN INstructIoNs
Please read these instructions
completely before you begin.
adorne
outlets are designed for
TM
installation in standard electrical
boxes. However, some of the instal-
lation methods vary slightly from
traditional methods. If you do not
understand these instructions or are
unsure of your abilities, seek the
assistance of a qualified electrician.
use only with legrand adorne
system.
(blanc)), Neutro (blanco)
(noir), Vivo (negro)
(nu),
Tierra (pelado)
TIPS
• Pre-fold wires into wall
box to make it easier to
fit them in the box when
outlet is connected.
• use caution to avoid
marring wall surface with
the metal frame.
Pour de plus amples informations ou
Para obtener más información y
visualiser des vidéos instructives et
videos demostrativos, visite
pratiques, rendez-vous sur
www.adornemyhome.com/install.
www.adornemyhome.com/install.
INstructIoNs d'INstallatIoN
INstruccIoNes de
Veuillez lire intégralement ces
INstalacIóN
instructions avant de commencer.
Por favor lea estas instrucciones en
les prises adorne
sont conçues
forma completa antes de empezar
TM
pour être installées dans des
a trabajar. los tomacorrientes
boîtiers électriques standard.
adorne
Toutefois, certaines méthodes
la instalación en cajas eléctricas
d'installation sont légèrement
estándares. sin embargo, algunos
différentes des méthodes
de los métodos de instalación
traditionnelles. si vous ne
pueden variar ligeramente de
comprenez pas ces instructions ou
los métodos tradicionales. si no
n'êtes pas sûr de vos capacités,
entiende estas instrucciones o
demandez l'assistance d'un
no está seguro de sus aptitudes,
électricien qualifié.
busque la ayuda de un electricista
calificado.
uniquement compatible avec le
utilice el producto únicamente con
système adorne legrand.
el sistema adorne de legrand.
HOT
WHITE
ASTUCES
• repliez préalablement
les fils dans le boîtier
mural afin de faciliter leur
insertion dans le boîtier
lors du branchement de
la prise.
• Faites bien attention
d'éviter d'abîmer la
surface du mur avec le
cadre métallique.
están diseñados para
TM
CONSEJOS
• Pliegue de antemano
los cables en la caja de la
pared para que sea más
fácil introducirlos en la
caja cuando el dispositivo
esté conectado.
• tenga cuidado para
evitar dañar la superficie
de la pared con el marco
de metal.
loading

Sommaire des Matières pour LEGRAND adorne ARTR202

  • Page 1 Fil de terre électricien qualifié. busque la ayuda de un electricista Cable a tierra calificado. use only with legrand adorne uniquement compatible avec le utilice el producto únicamente con system. système adorne legrand. el sistema adorne de legrand.
  • Page 2 50 Boyd Avenue syracuse, NY 13209 syracuse, NY 13209 No: 340951 – 03/12 Rev. 1 60 Wodlawn Street 570 Applewood Crescent West Hartford, CT 06110 Vaughan, ONT L4K 4B4 © Copyright 2012 Legrand All Rights Reserved. 1.877.BY.LEGRAND 905.738.919 5 (295.3472) www.legrand.ca www.legrand.us...

Ce manuel est également adapté pour:

Adorne pass and seymour artr202w4