Liens rapides

Owner's Instruction and Operation Manual
Model Numbers:
AW2520E-P • AW2520E-BP
AW2520E-L • AW2520E-BL
Report Number: F19-487
Tested Per EPA Methods ASTM E2515, ASTM
E3053-ATM and CSA B415
Certified to UL 1482-2022, CAN/ULC S627:2023
Mobile home/transportable building approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift
compromises during the installation of this heater. Contact local building or
fire officials about permits, restrictions and installation requirements in your
area. NEVER OPERATE THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury,
or even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
853582L-1505N
www.P65warnings.ca.gov
Ph. 800-750-2723
Table des Matières
loading

Sommaire des Matières pour Ashley AW2520E-P

  • Page 1 Owner’s Instruction and Operation Manual Model Numbers: AW2520E-P • AW2520E-BP AW2520E-L • AW2520E-BL Report Number: F19-487 Tested Per EPA Methods ASTM E2515, ASTM E3053-ATM and CSA B415 Certified to UL 1482-2022, CAN/ULC S627:2023 Mobile home/transportable building approved * All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
  • Page 2 The instructions pertaining to the installation of your wood stove comply with UL 1482-2022 and CAN/ULC S627:2023 standards. This manual describes the installation and operation of the Ashley, AW2520E wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2020.
  • Page 3: Installation Checklist

    INSTALLATION CHECKLIST Your Wood Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi-pro/ CUSTOMER SERVICE 1-800-750-2723 ext 5050 Text to 423-301-5624 Email to: Customerservice@usstove.com COMMISSIONING CHECKLIST This Checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4: Tools And Materials

    ASSEMBLY INSTRUCTIONS FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 TOOLS AND MATERIALS ASH PAN ASSEMBLY You will need a drill with a 1/8” bit to install sheet metal Remove ash pan from firebox. Under the firebox, screws into connector pipe. A 5/16” socket/wrench there are two brackets;...
  • Page 5 ASSEMBLY INSTRUCTIONS FIREBRICK CONFIGURATION AIR DEFLECTOR ASSEMBLY Replace the Firebrick as shown in the illustration. Use the provided screws to attach the air deflector to the rear of the unit. INSTALLATION SAFETY NOTICE SAFETY NOTICE • IF THIS STOVE IS NOT PROPERLY INSTALLED, THIS ROOM HEATER SHALL NOT BE INSTALLED A HOUSE FIRE MAY RESULT.
  • Page 6: Floor Protector

    INSTALLATION FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050 not be hooked up to a hot air distribution system under the horizontal run that extends 2” beyond since an excessive accumulation of heat may occur. each side of the flue pipe. A wood stove must never be installed in a hallway •...
  • Page 7: Outside Combustion Air

    INSTALLATION OUTSIDE COMBUSTION AIR Slide the hose clamp over the aluminium flex pipe. Then slide the flex pipe over the air intake tube of Your wood stove is approved to be installed with an the stove. Next tighten the hose clamp over the end outside air intake (4FAK) which is necessary for a of the aluminium flex hose.
  • Page 8 INSTALLATION SECURING APPLIANCE’S WITH LEGS TO more than two 90 degrees elbows in the smoke exhaust system. The installation of a “barometric THE FLOOR draft stabilizer” (fireplace register) on a smoke The bracket engages around the square exhaust system is prohibited. Furthermore, the extrusion of the leveling bolt inserted into the installation of a draft damper is not recommended.
  • Page 9: Factory Built Chimney

    INSTALLATION Your wood stove may be hooked up with a 6” factory- package or wall pass-through and “T” section built or masonry chimney. If you are using a factory- package, firestops (where needed), insulation built chimney, it must comply with UL 103 or CAN/ shield, roof flashing, chimney cap, etc.
  • Page 10: Combustible Wall Chimney Connector Pass-Throughs

    INSTALLATION METHOD B - 9” (229 mm) Clearance to Combustible Concrete Cap Wall Member: Using a 6” (153 mm) inside diameter, Fireclay Flue Liner With listed, factory-built Solid-Pak chimney section with Airspace 1” Clearance with Firestop insulation of 1” (26 mm) or more, build a wall pass- through with a minimum 9”...
  • Page 11 INSTALLATION METHOD D - 2” (51 mm) Clearance to Combustible NOTES: Wall Member: Start with a solid-pak listed factory • Connectors to a masonry chimney, excepting built chimney section at least 12” (304 mm) long, method B, shall extend in one continuous section with insulation of 1”...
  • Page 12 OPERATION INSTRUCTIONS NEVER OPERATE THIS PRODUCT WHILE UNATTENDED OPERATING SAFETY PRECAUTIONS CAUTIONS: HOUSE FIRE HAZARDS • NEVER OVERFIRE THIS APPLIANCE BY • DO STORE WOOD FLOOR BUILDING EXCESSIVELY HOT FIRES AS A PROTECTOR, UNDERNEATH STOVEPIPE(S) HOUSE/BUILDING FIRE MAY RESULT. YOU OR ANYWHERE WITHIN CLEARANCES TO ARE OVERFIRING THE APPLIANCE IF IT COMBUSTIBLE SURFACES SPECIFIED FOR...
  • Page 13 OPERATION INSTRUCTIONS wax, and similar substances to start a fire in an • Keep the air control fully open and close the affected wood heater. door. If the wood ignites within 90 seconds from the time it was placed in the stove, your wood is Burning these materials may result in the release correctly dried.
  • Page 14: Fueling Instructions

    OPERATION INSTRUCTIONS series of three initial burns. The appliance should be Pull the air control out fully. Light the newspaper allowed to cool off between each burn. The first two and leave the door slightly open for about a minute. burns should be small fires and low temperatures NOTE: You may have to leave it open a bit longer, (250°F) for a duration of 20 minutes each.
  • Page 15: Blower Operation

    OPERATION INSTRUCTIONS VISIBLE SMOKE For a low burn setting once the high burn (or medium) fuel load is burned down to an established The amount of visible smoke being produced can be coal bed, rake and level the coalbed. Load the an effective method of determining how efficiently unit with 33 lbs of cordwood and close the door the combustion process is taking place in the given...
  • Page 16: Chimney Maintenance

    CHIMNEY MAINTENANCE NEVER OPERATE THIS PRODUCT WHILE UNATTENDED • Leave the air control fully open for about 5 min. CAUTION: every time you reload the stove to bring it back DO NOT OVERFIRE APPLIANCE. YOU ARE to proper operating temperatures. The secondary OVERFIRING IF ANY PART OF THE APPLIANCE combustion can only take place if the firebox is GLOWS RED.
  • Page 17: Glass Care

    CHIMNEY MAINTENANCE SMOKE & CO MONITORS • Never wash the glass with a product that may scratch. Use a specialized product, available in Burning wood naturally produces smoke and the stores where wood stoves are sold. The glass carbon monoxide(CO) emissions. CO is a poisonous should be washed only when cold.
  • Page 18: How To Order Repair Parts

    HOW TO ORDER REPAIR PARTS For Parts Assistance, Call 800-750-2723 ext 5051 or Email: parts@usstove.com , or order at www.myreplacementparts.com The information in this owner’s manual is specific to your unit. When ordering replacement parts the information in this manual will help to ensure the correct items are ordered. Before contacting customer service write down the model number and the serial number of this unit.
  • Page 19: Repair Parts

    REPAIR PARTS Part # Description 40292A 6” Flue Collar 88042 1/4” Rope Gasket 25845 Air Deflector 891492 Blower Assembly (CB36) 26060 Rear Shield 610926 Rear Ashpan (AW2520E-BP) 29243 Pedestal (AW2520E-BP) 29065 Pedestal Front (AW2520E-BP) Pedestal Base Weldment 610969 (AW2520E-BP) 610968 Ashpan Housing (AW2520E-BL) 40566 Cast Iron Leg...
  • Page 20 REPAIR PARTS Part # Description 88325 Kao Wool Blanket 88138 Ceramic Fiber Board 860015 Secondary Air Tube (Ø1/8) 29248 Left Brick Panel 29247 Right Brick Panel 24103A Half Firebrick (4-1/2 X 4-1/2) 40561 Ash Plug 891530A Firebrick (4.5 X 7.5 X 1.25) 89066A Firebrick (4-1/2 X 9) 891414A...
  • Page 21: Service Record

    SERVICE RECORD It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 22 NOTES © 2024 United States Stove Company...
  • Page 23 NOTES © 2024 United States Stove Company...
  • Page 24 NOTES © 2024 United States Stove Company...

Ce manuel est également adapté pour:

Aw2520e-bpAw2520e-lAw2520e-bl

Table des Matières