Télécharger Imprimer la page

Element4 Power Fan Instructions D'installation page 32

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ASSEmBLy AND INSTALLATIoN
7.
Replace Control box cover.
8.
Check the speed adjustment, but note that if the speed is set too low the fan will revert to high
speed after 15 seconds and power will no longer be supplied to the black lead / solenoid.
Reset a Fan Lock out
Once the Fan has locked out to high speed mode the power must be cycled to reset the unit.
Once the power is restored 15 seconds must pass before the fan speed will switch to the set value.
Final speed adjustment
Advance speed control 10° clockwise to account for severe weather and avoid nuisance shut downs.