4. HYDRAULIC SYSTEM
ASSIGNEMENT
If your installation has several separate
hydraulic circuits containing their own
pumps or boilers, you may want to drive
each pump/boiler separately from specific
heating receivers or thermostatic actua-
tor(s). With Vision
®
ate and control up to 4 hydraulic circuits.
Each of the circuits will have an RF remote
circuit receiver linked to it that will activate
the intended pump and boiler. If at least
one heating receiver or thermostatic actu-
ator on the circuit has a demand, the linked
circuit receiver will operate and activate the
pump (and / or boiler).
STEP 1:
Define which device is assigned
to a hydraulic circuit
With the plan of your installation, define
which devices are on "circuit 1".
Then, pair and configure all these devices
on circuit 1.
, enter a zone (room) that belong
to circuit 1,
, and select one device of circuit 1
(radio connecting box, radio receiver or radia-
tor thermostatic head)
Now you have entered the
configuration menu of the device.
the menu "Heating settings" and make
sure that "Hydraulic heating" is selected
You can now select the
hydraulic circuit linked to this receiver (e.g.
circuit 1).
BT-CT03-RF-IOM-FR-W-EN-10-23
Wireless you can cre-
Select
Repeat the procedure for each device of
the room (zone) you want to link to the
hydraulic circuit. Further devices can be
selected using the buttons
top of the device name.
Repeat the procedure for each room (zone)
that you want to link to hydraulic circuit
1. If you have assigned all rooms / devic-
es, repeat the procedure for any further
hydraulic circuits.
STEP 2:
pairing radio receiver hydraulic
circuit with the central unit
For each circuit, you can link a circuit receiver
to drive the pump devices, valve drive or
heat / cool generator of the circuit. This can
be done for example by BT-WR02 RF.
Select "Circuit", then select the number
of the circuit, e.g. circuit 1. Put the radio
receiver in pairing mode (BT-WR02 RF).
Repeat the procedure for additional
hydraulic circuits.
Heat and Cool installations
If your installation includes both heating and
cooling functions, you can switch either
from Heat to Cool manually or automati-
cally:
• If you have a WFC-03 HCM RF in your
installation set as "Master" (refer to
Manual instruction of the device) then
all is automatic you don't have to do
anything
• For all other cases, you have to do the
switch manually:
then
There you will have the choice between
"Heating Only", "Cooling Only" or "Manual
Reversible".
or
at the
go in "H&C".