CALORITEC OK3 Serie Instructions D'installation

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Infrared Radiant Heaters
OK3 Series
Installation Instructions
WARNING. Failure to follow this Installation &
Maintenance Instructions could result in personal
injury, death or property damage. Improper
WARNING
installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire,
electrical shock, or other conditions, which could
result in personal injury or death.
HIGH TEMPERATURE, RISK OF FIRE, FIRE/EXPLOSION
HAZARD WARNING. During operation, take
precautions to ensure that combustible materials are
CAUTION
always kept at a safe distance from the radiant
energy, as required by the codes and rules of the
jurisdiction of installation. This heater is not intended
for use in hazardous areas where flammable vapousr,
gases, or liquids or other combustibles are present.
Remember objects placed under an infrared heater
can take a while to reach stabilized temperatures. If
you are unsure of the suitability of the heater for the
intended applications. check with the factory for
recommendations. Failture to comply can result in
personal injury and/or property damage.
1. Description
Read all instructions before installing and using the heater.
1.
The OK3 radiant heaters are suitable for comfort heating
use in non-hazardous areas protected from rain, snow
or splashing, where heating element temperatures
in excess of 750°C (1382°F) will not present the risk of
fire or explosion. The heater does not present a safety
hazard when it is installed, operated and maintained in
accordance with these instructions.
2.
The OK3 heater has two U-shaped metal sheath heating
elements factory interconnected in series or parallel
depending on voltage. Never change heaters which have
been factory series connected to a parallel connection.
3.
Minimum space clearances from combustibles, when
heaters are horizontally mounted and installed, as listed
in Table 1.
Table 1 – Minimum Space Clearance
From nearest wall
From the ceiling
Minimum Spacing
60 cm (24")
30 cm (12")
38 cm
[15"]
Figure 1 – Mounting Clearances
4.
To facilitate mounting, the heater has four ¼"-20
mounting holes located at each top corner of the
housing. Either chain mounting (use eye bolts) or bolting
to a non-combustible sliding support (slotted holes) is
adequate provided that the spacing instructions as given
in 3.0 are followed. Chain mounting is preferred since
rigidly mounted heaters are susceptible to warping.
2. Installation
3. Installation
WARNING. The system designer is responsible for the
safety of this equipment and adequate backup
controls and safety devices must be installed. Failure
WARNING
to comply could result in personal injury and/or
properly damage.
CAUTION. Heaters must be wired by qualified
personnel in compliance with local codes
CAUTION
1.
Verify that the nameplate voltage and wattage are
suitable for use on the available electrical power supply.
Do not connect the heater to an electrical supply voltage
other than shown on the product label.
WARNING. Insulation contamination or moisture
accumulation can cause fault to the elemtn sheath
generating arcing and releasting molten metal. Install
WARNING
proper ground fault protection to prevent personal
injury and/or property damage.
2.
The connection box volume is 3100 cm³ (190 in³).
3.
Supply conductors to the heater must be suitable for
110°C (230°F). The ground wire from the supply shall be
connected to the grounding connection located in the
connection box.
60 cm
[24"]
MI182.Rev.10.02 April 2024
Printed in Canada
ISO 9001

Publicité

loading

Sommaire des Matières pour CALORITEC OK3 Serie

  • Page 1 Infrared Radiant Heaters OK3 Series Installation Instructions ISO 9001 WARNING. Failure to follow this Installation & Maintenance Instructions could result in personal injury, death or property damage. Improper WARNING installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions, which could result in personal injury or death.
  • Page 2 The connection box has eight dual knockouts, ½” or ¾” Do not operate any heater after it malfunctions. and two dual knockouts ¾” or 1”. The standard Type 1 Disconnect power at service panel and have heater enclosure is suitable for dry, indoor locations only in non- inspected by a qualified electrician before reusing.
  • Page 3 PLEASE ADHERE TO INSTRUCTIONS IN THIS MANUAL Failure to do so may be dangerous and may void certain provisions of your warranty. For further assistance, please call 24hr hotline: 1-877-325-3473 (U.S.A. and Canada) Please have model and serial numbers available before calling. WARRANTY: No warranty applies to paint fi nishes except for manufacturing Under normal use the Company warrants...
  • Page 4 NOTES NOTES...
  • Page 5 Radiateurs infrarouges Séries OK3 Instructions d’installation, d’opération et d’entretien ISO 9001 Table 1 – Dégagements minimum de l’espace ATTENTION. Le non-respect de ces instructions d'installation et d'entretien pourrait entraîner des Espacement min. blessures corporelles, la mort ou des dommages ATTENTION matériels.
  • Page 6 Le volume du boîtier de raccordement est de 3100 cm 5. Entretien (190 po ATTENTION. Coupez l’alimentation avant tout Les fils de raccordement doivent pouvoir supporter une installation ou entretien de ce radiateur. Sinon un bris température de 110 °C (230 °F). Le fil de mise à la terre de pourrait occasionner des blessures et/ou des l’alimentation doit être relié...
  • Page 7 NOTES NOTES...
  • Page 8 VEUILLEZ RESPECTER LES CONSIGNES DE CE MANUEL Á défaut de quoi vous prenez des risques et certaines dispositions de votre garantie seront annulées. Pour de l’aide supplémentaire, veuillez composer notre numéro d’urgence 24 h par jour: 1-800-410-3131 (U.S.A. et Canada). Merci de préparer vos numéros de modèle et de série avant d’appeler. GARANTIE: Aucune garantie ne s’applique à...