Oil capacity to the correct level according to the model is:
➢ Model TURBO2800
➢ Model TURBO3300E
➢ Model TURBO3300E
➢ Model TURBO3300E
7. Install the oil filling plug again.
IMPORTANT: In order to comply with environmental requirements, the used oil
must be placed in a sealed container and taken to the service station for recycling.
Do not discard the trash and do not spill on the floor.
8.2 Air filter maintenance
NOTE: A dirty air filter will restrict the air flow in the carburettor, which will
cause incorrect combustion resulting in serious problems for the engine. Clean the
filter regularly according to the maintenance plan in this manual and with more
frequency in dusty areas.
NOTE: Never operate the generator without the air filter, otherwise this will
cause a fast engine abrasion.
WARNING: Do not use gasoline or solvents for low ignition point when
cleaning the filter. They are flammable and explosive under certain conditions.
0.6 litros
0.6 litros
1.1 litros
1.1 litros
53
MAX LECEL
MINIMUN LEVEL

Publicité

loading

Ce manuel est également adapté pour:

Turbo7000e