Safety instructions

Warning! Failure to comply with the specified precautionary measures may cause serious injury to persons or damage to property.
The installation and commissioning may only be performed by suitably qualified persons, technicians or installers in
compliance with safety regulations. Damage due to improper installation and commissioning, defective connectors
on cables or any other incorrect handling will void the warranty.
CAUTION: The safety requirements are according to EN 60728-11 and must be observed.
Disconnect mains power before working on electrical systems.
Any additional electrical wiring requirements should always be installed by a suitably qualified person(s).
Installation or service work should NEVER be undertaken during electrical / thunderstorms.
Introduction
The purpose of this guide is to enable the successful installation of the Triax TVC 06 QUAD and TVQ 06 QUATRO products.
This guide assumes that;
The converter is connected to a suitable Triax Passive Optical Network (PON),
providing a minimum optical signal levels of -12/-15 dBm at the connection point of the converter.
The converter has been installed in a dry environment and mounted with suitable fixings.
The installation is carried out by a competent person.
All ferrule end faces of the FC/PC optical connectors are cleaned prior to making
a connection using a suitable fibre optic cleaning kit.
Cables and Connections
Cables used should be industry approved coaxial cable and should be terminated using an F type connector. Fibre optic
cable should be Triax approved single mode with FC/PC connections.
Mounting
The device can be fixed on the wall or on a metal plat in a distributor box by using two 4 mm screws directly.
115 mm
Next connect the FC/PC fibre connector into the optical input of the converter
(ensuring the end is cleaned first) as per the following diagram.
Align the key-way on the FC-PC
connector, with the key-way on the fibre
receptacle. Push the connector firmly
into the socket.
1
Connector key-way
Receptacle key-way
Attention: Never look with the eyes into a fibre line or fibre connector when an optical transmitter is connected!
The laser light is not visible but could damage the eye.
2/8
115 mm
Ensure the key-way are firmly located
be- fore rotating the coupling ring clock-
wise onto the receptacle - se Fig. 3
2
Push firmly to locate key-ways
Coupling ring
LED "Orange"
indicates when RF
power is present
LED "Green"
indicates that unit is
DC power supplied
NOTE: Failure to follow these instruction
correctly will result in attenuation
3
Rotate clock-wise to finish