Before contacting a service technician, your local product dealer or
Unique Off-Grid Appliances, please check the following points.
If you contact a technician to repair a fault listed below, or to repair a
fault caused by misuse, abuse, or faulty installation, a charge will be
made even if the appliance is under warranty.
PROBLEM
Appliance is
connected
to power,
but does not
operate
Appliance is
operating, but
the interior
(cabinet) is not
cold
The door will
not open
TROUBLESHOOTING
SOLUTION
• Check if 12V or 24V DC is present at the
appliance. If not, check all connections and the
system battery voltage.
• Check that the polarity is correct: positive (+)
is connected to positive (+), and negative (-) is
connected to negative (-).
• Check the fuse. If blown, replace with a new one
(see page 11 for details).
• The primary problem with a non-functioning
appliance is due to a voltage drop to the
compressor, which causes the unit to fail
to start due to "low voltage". Typically a
connection is not as tight as it should be, or the
wire size to the compressor is too small. The
low voltage problem occurs instantly at start-up
and can be difficult to detect with a volt meter
because it happens so quickly (<100ms)
• Allow the appliance at least 4 hrs to cool down
once turned on.
• Check that the thermostat control knob is
turned to the correct setting relevant to the
room/ambient temperatures.
• Check that the room/ambient temperature
is not approaching the internal operating
temperature and does not exceed to 100˚F
(38˚C).
• Has too much warm food been added to the
fridge/freezer recently? If so, it will take some
time for the appliance to return to temperature.
• Does the cabinet have adequate ventilation
around the side walls, allowing it to transfer
heat properly? (See Installation section)
• Has the door just been opened? If so, leave the
appliance closed for a few minutes to allow the
air pressure to equalize and try again.
17