21. Switch off the machine before removing the plug.
22. When unplugging, pull the plug, not the supply cord.
23. The plug of the power supply cord must be removed
from the socket-outlet when not in use and before
commencing cleaning of the machine or undertaking
maintenance operations.
24. DO NOT pull or carry by the supply cord. DO NOT use
cord as a handle, close door on cord or pull cord around
sharp edges or corners.
25. WARNING: Keep the power supply cord clear of moving
parts. During operation hazard may occur when running
the machine over the power supply cord.
26. DO NOT kink or twist the power cord and keep cord
away from heated surfaces.
27. DO NOT operate switches or touch the mains plug with
wet hands as this may cause electric shock.
28. The power supply cord plus any extension leads should
not exceed 30 metres in total. The cross section of an
extension cable wiring must be at least 2.5mm².
Transporting the machine
Incorrect lifting techniques may result in personal injury. We
advise that the manual handling regulations are followed.
Carefully wrap the power cord and store in dry indoor
location. Do not expose the machine to rain or moisture. Lift
the machine by the carrying handle to transport.
UK Model only
The cord is equipped with a 13 amp fuse. If replacing fuse,
use a 13 amp fuse confirming to BS1362. Do not use the
machine if fuse cover is missing.
After sales service
Truvox machines are high quality machines that have been
tested for safety by authorised technicians. It is always
apparent that after longer working periods, electrical and
mechanical components will show signs of wear and tear or
ageing. To maintain operational safety and reliability the
following service interval has been defined: Every year or
after 250 hours. Under extreme or specialised conditions
and/or
insufficient
maintenance,
intervals are necessary. Use only original Truvox spare
parts. Use of other spare parts will invalidate all warranty and
Recommended Spares & Accessories
Part No.
20-0192-0000
20-0172-0000
20-0168-0000
20-0169-0000
RD277
DS-076
Fault diagnosis
The following simple checks may be performed by the operator:
Trouble
Machine not working
Loss of suction
Motor is not running
* If the fuse blows several times, the machine should be checked by an authorises Service Agent
3
shorter
maintenance
Item
HEPA Filter + Pre Filter (inclusive of HEPA Holder + 1 x HEPA 13 filter + 5 x Vac inlet filter)
Dust bag (Pack of 10)
Hose
Telescopic wand
Floor tool
Crevice tool
Reason
• Lack of voltage/electrical supply
• Bag full
• Blocked hose or wand
• Motor not working
• Broken switch
• Defective power cord
• Defective motor
liability claims. Should you require after sales service please
contact the supplier from whom you purchased the machine,
who will arrange service. Repairs and servicing of Truvox
products should only be performed by trained staff. Improper
repairs can cause considerable danger to the user.
Guarantee
Your product is guaranteed for one year from the date of
original purchase, or hire purchase, against defects in
materials or workmanship during manufacture. Within the
guarantee period we undertake at our discretion, to repair or
replace free of charge to the purchaser, any part found to be
defective, subject to the following conditions:
C
ONDITIONS
1. Claims made under the terms of the guarantee must be
supported by the original invoice/bill of sale issued at the
time of sale, or the machine Serial No.
2. For claims under this guarantee contact the supplier from
whom you purchased the product who will arrange the
appropriate action. Do not initially return the product as
this could result in transit damage.
3. Neither Truvox nor its distributor shall be liable for any
incidental or consequential loss.
4. This guarantee is governed by the laws of England.
5. This guarantee does not cover any of the following:
Periodic maintenance, and repair or replacement
of parts due to normal wear and tear.
Damage caused by accident, misuse or neglect, or
the fitting of other than genuine Truvox parts.
Defects in other than genuine Truvox parts, or
repairs, modifications or adjustments performed by
other than a Truvox service engineer or authorised
service agent.
Costs and risks of transport relating directly or
indirectly to the guarantee of this product.
Consumable items such as, brushes, drive discs,
filters and vacuum skirts.
• This guarantee does not affect your statutory rights, or
your rights against the supplier arising from their sales or
purchase contract. Truvox International Limited policy is
one of continual product development and we reserve the
right
to
alter
specifications
Remedy
• Check fuse *, supply cord, plug and socket
outlet
• Replace bag
• Remove obstruction
• Contact supplier
• Contact supplier
without
prior
notice.