0
Velocità
Geschw.
Vitesse
Speed
>28°
FUNCTIONS
Temperature threshold regulating trimmer.
1)
Operating mode selector switch:
2)
MANUAL:
- full speed operation
AUTOMATIC: - full speed operation when the temperature is higher than about 50 C°.
- reduced speed operation when the temperature is between the
threshold set in advance (28 / 35°C) and about 50 C°.
Operating signalling LED
3)
- green :
fan powered.
- yellow :
automatic operation at reduced speed.
- red :
manual or automatic operation at full speed.
Wires to be connected to a 12V c.c. fuse protected line (minimum wire size 1mm²).
4)
INSTALLATION INSTRUCTIONS
Install the fan in the upper grille of the refrigerator, in order to allow the air circulation from indoor to
outdoor.
Install the fan in the best possible way, depending on the type of the grille, with the sensor towards
the inside; To install the control panel use the bottom of the box like a drilling template (a 13mm
hole is needed for the passage of the connector).