  • Page 1 PAP 350 PAP 420...
  • Page 3 ESPAÑOL ÍNDICE 1. GENERALIDADES ........................3 2. NORMAS DE SEGURIDAD Y MARCADO “CE” ................ 3 3. ADVERTENCIAS DE SEGURIDAD ................... 3 4. CARACTERÍSTICAS TÉCNICAS ....................4 5. MANIPULACIÓN ........................4 6. RECEPCIÓN ..........................4 7. DIMENSIONES ........................5 8. EMPLAZAMIENTO ........................5 8.1.
  • Page 4 1. GENERALIDADES • Le agradecemos la confi anza que ha depositado en nosotros mediante la compra de este aparato. Usted ha adquirido un producto de calidad que ha sido totalmente fabricado según las reglas técnicas de seguridad reconocidas y conformes a las normas de la CE. •...
  • Page 5 • No introduzca ningún objeto a través de la rejilla de salida de aire. • La limpieza y el mantenimiento a realizar por el usuario no deben realizarlos los niños sin supervisión. • Para la limpieza o mantenimiento del purifi cador, desconéctelo de la alimentación. •...
  • Page 6 7. DIMENSIONES Modelo Peso (mm) (mm) (mm) (kg) PAP 420 H14 PAP 350 CA H14 PAP 350 VOC H14 8. EMPLAZAMIENTO • Una vez fuera de la caja, ubique el purifi cador en el local o habitación sobre el que se desea purifi...
  • Page 7 Fig. 1 8.1. COMPONENTES DEL EQUIPO El purifi cador PAP está compuesto por los siguientes componentes: Vista por la parte frontal Vista por la parte trasera Difusor salida aire Potenciómetro ajuste velocidad Tapa acceso filtros Interruptor paro-marcha Ruedas Ruedas 8.2. CONDICIONES DE UTILIZACIÓN •...
  • Page 8 Para retirar las bolsas de los fi ltros, siga el siguiente procedimiento: • Asegúrese que la unidad no se encuentra conectada a la red eléctrica. • Utilice guantes protectores en la manipulación del equipo. • Con la ayuda de la llave suministrada con el equipo, afl oje y retire los tornillos que sujetan la tapa de acceso a fi...
  • Page 9 9.1. MODELO PAP-420 H14 Ajuste de velocidad recomendada en función de la aplicación y dimensiones del local: Reducir Aumentar velocidad velocidad Locales con poca ocupación (recepción y habitaciones de hotel, consultorios médicos, den- tistas, despachos): Superfi cie (m Altura Locales con ocupación media (ofi cinas, salas de reuniones, establecimientos comerciales, aulas): Superfi...
  • Page 10 9.2. MODELO PAP-350 CA H14 Y PAP-350 VOC H14 Ajuste de velocidad recomendada en función de la aplicación y dimensiones del local: Reducir Aumentar velocidad velocidad Locales con poca ocupación (recepción y habitaciones de hotel, consultorios médicos, den- tistas, despachos): Superfi...
  • Page 11 10. MANTENIMIENTO PREVENTIVO Pese a que las operaciones de mantenimiento no suelen ser complicadas, recomendamos que éstas sean realizadas por personal cualifi cado. En S&P disponemos de una extensa red de Servicios Técnicos que podrán ofrecer su asistencia técnica tanto para la puesta en mar- cha de los equipos como realizar el mantenimiento de fi...
  • Page 12 Debido a esta dependencia de factores, no es posible establecer unas frecuencias de mante- nimiento exactas. A modo orientativo se pueden seguir las siguientes pautas: • Control visual/limpieza del prefi ltro: Cada 2 meses. • Sustitución del prefi ltro: Entre 6 meses y 1 año dependiendo del uso. •...
  • Page 13 Tabla de recambios de fi ltros Modelo Prefi ltro F7 Filtro CA/VOC Filtro absoluto H14 purifi cador Código Modelo Código Modelo Código Modelo PAP 420 H14 5800028500 AFR F7 PAP 420/350 5800028600 AFR H14 PAP 420/350 PAP 350 CA H14 5800028500 AFR F7 PAP 420/350 5800028700 AFR CA PAP 350 5800028600 AFR H14 PAP 420/350 PAP 350 VOC H14 5800028500 AFR F7 PAP 420/350 5800028800 AFR VOC PAP 350 5800028600 AFR H14 PAP 420/350 10.2.
  • Page 14 ENGLISH INDEX 1. OVERVIEW ..........................15 2. SAFETY STANDARDS AND “EC” MARKING ................. 15 3. SAFETY INSTRUCTIONS ...................... 15 4. TECHNICAL CHARACTERISTICS ..................16 5. HANDLING ........................... 16 6. RECEPTION .......................... 16 7. DIMENSIONS ........................17 8. LOCATION ..........................17 8.1.
  • Page 15 1. OVERVIEW • We appreciate the trust you have placed in us by purchasing this device. You have pur- chased a high-quality product that has been manufactured in strict compliance with recog- nized technical regulations regarding safety, and in accordance with EC standards. •...
  • Page 16 • Do not insert any object through the air output grille. • Cleaning and user maintenance shall not be made by children without supervision. • Before carrying out any maintenance work, or during long periods without use make sure that the purifi er has been disconnected from the mains. •...
  • Page 17 7. DIMENSIONS Model Peso (mm) (mm) (mm) (kg) PAP 420 H14 PAP 350 CA H14 PAP 350 VOC H14 8. LOCATION • Once out of the box, locate the purifi er in the premise or room where you need to purify the air.
  • Page 18 Fig. 1 8.1. PURIFIER COMPONENTS The PAP purifi er is made up of the following components: Front view Rear view Air outlet diffuser Potentiometer of speed Cover adjustment of filters access On-off switch Wheels Wheels 8.2. USE CONDITIONS • PAP units are indicated for air purifi cation in commercial and clean sanitary environ- ments.
  • Page 19 a plastic bags. Before switching on the unit, it is necessary to remove these bags and reas- semble the fi lters, making sure that the air direction matches the one indicated in the fi lter frame. To remove the fi lter bags, follow the next procedure: •...
  • Page 20 9.1. PAP-420 H14 MODEL Recommended speed setting depending on the application and room dimensions: Reduce Increase speed speed Premises with little occupation (reception, hotel rooms, medical offi ces, dentists, offi ces): Surface (m Height Premises with medium occupation (offi ces, meeting rooms, commercial establishments, classrooms): Surface (m Height...
  • Page 21 9.2. PAP-350 CA H14 AND PAP-350 VOC H14 MODELS Recommended speed setting depending on the application and room dimensions: Reduce Increase speed speed Premises with little occupation (reception, hotel rooms, medical offi ces, dentists, offi ces): Surface (m Height Premises with medium occupation (offi ces, meeting rooms, commercial establishments, classrooms): Surface (m Height...
  • Page 22 10. PREVENTIVE MAINTENANCE Although maintenance operations are not usually complicated, we recommend that they be carried out by qualifi ed personnel. At S&P we have an extensive network of Technical Services that will be able to offer technical assistance for both equipment startup and fi lter maintenance and interior cleaning of the unit.
  • Page 23 • CA / VOC fi lter replacement: Between 6 months and 1 year depending on use. • H14 Absolute fi lter: Between 1 year and 2 years depending on use. Process for the fi lter disassembly Access to fi lters is done from the top of the appliance. To access these, follow the next pro- cedure: •...
  • Page 24 10.2. FANS • It is recommended to check the status of the fan every 6 months. • In case that dust or dirt accumulation is detected on the impeller surfaces, fi rst clean it with a damp cloth and then with some disinfectant product compatible with polyamide.
  • Page 25 FRANÇAIS SOMMAIRE 1. GÉNÉRALITÉS ........................26 2. NORMES DE SECURITES ET MARQUAGE “CE” ..............26 3. RECOMMANDATIONS DE SÉCURITÉ ................... 26 4. CARACTÉRISTIQUES TECHNIQUES ..................27 5. MANIPULATION ........................27 6. RECEPTION .......................... 27 7. DIMENSIONS ........................28 8. EMPLACEMENT ........................28 8.1.
  • Page 26 1. GÉNÉRALITÉS • Nous vous remercions de la confi ance que vous nous accordez en achetant cet appareil. Vous avez acheté un produit de qualité entièrement fabriqué conformément aux règles techniques de sécurité reconnues et conformes aux normes CE. • Avant d’installer et d’utiliser ce produit, lire attentivement ces instructions qui contiennent d’importantes indications pour votre sécurité...
  • Page 27 personne responsable de leur sécurité, d’une surveillance ou d’instructions préalables concernant l’utilisation de l’appareil. Les enfants ne doivent pas jouer avec l’appareil. • Ne pas placer l’appareil près d’une source de chaleur, exposé au soleil ou sur une surface chaude. 4.
  • Page 28 7. DIMENSIONS Modèle Poids (mm) (mm) (mm) (kg) PAP 420 H14 PAP 350 CA H14 PAP 350 VOC H14 8. EMPLACEMENT • Une fois sorti de l’emballage, localisez le purifi cateur dans la pièce ou la pièce dans laque- lle vous souhaitez purifi er l’air. •...
  • Page 29 Fig. 1 8.1. COMPOSANTS DE L’APPAREIL Le purifi cateur PAP est composé des éléments suivants: Vue de face Vue arrière Diffuseur de sortie d'air Potentiomètre Panneau de réglage de d'accès filtres la vitesse Interrupteur marche-arrête Roues Roues 8.2. CONDITIONS D’UTILISATION •...
  • Page 30 ment disponible en modèle PAP 420), ils sont fournis dans des sachets plastique. Avant la mise en marche de l’unité, il est nécessaire de retirer ces sachets et de monter les fi ltres en s’assurant que la direction de l’air coïncide avec celle indiquée sur le cadre du fi ltre. Pour retirer les sachets des fi...
  • Page 31 9.1. MODÈLE PAP-420 H14 Réglage de la vitesse recommandée en fonction de l’application et des dimensions des lo- caux: Réduire Augmenter la vitesse la vitesse Locaux peu occupés (réception et salles d’hôtel, cabinets médicaux, dentistes, bureaux): Surface (m Hauteur Locaux à occupation moyenne (bureaux, salles de réunion, établissements commerciaux, sa- lles de classe): Surface (m Hauteur...
  • Page 32 9.2. MODÈLE PAP-350 CA H14 ET PAP-350 VOC H14 Réglage de la vitesse recommandée en fonction de l’application et des dimensions des lo- caux: Réduire Augmenter la vitesse la vitesse Locaux peu occupés (réception et salles d’hôtel, cabinets médicaux, dentistes, bureaux): Surface (m Hauteur Locaux à...
  • Page 33 10. MAINTENANCE PRÉVENTIVE Bien que les opérations de maintenance ne soient généralement pas compliquées, nous re- commandons que celles-ci soient effectuées par du personnel qualifi é. Chez S&P, nous avons un vaste réseau des services techniques qui seront en mesure d’offrir une assistance technique à...
  • Page 34 Filtre absolu H14 et fi ltres anti-odeurs, gaz et VOC Ces fi ltres n’ont pas besoin d’entretien. Une fois les fi ltres colmatés, il faut procéder à leur remplacement. Les fréquences de maintenance des fi ltres dépendront de plusieurs facteurs tels que les heu- res d’utilisation, le débit de régulation, ainsi que le degré...
  • Page 35 Tableau des pièces de rechange des fi ltres Modèle Prèfi ltre F7 Filtre CA/VOC Filtre absolu H14 purifi cateur Code Modèle Code Modèle Code Modèle PAP 420 H14 5800028500 AFR F7 PAP 420/350 5800028600 AFR H14 PAP 420/350 PAP 350 CA H14 5800028500 AFR F7 PAP 420/350 5800028700 AFR CA PAP 350 5800028600 AFR H14 PAP 420/350 PAP 350 VOC H14 5800028500 AFR F7 PAP 420/350 5800028800 AFR VOC PAP 350 5800028600 AFR H14 PAP 420/350 10.2.
  • Page 36 S&P SISTEMAS DE VENTILACIÓN, S.L.U. C. Llevant, 4 Polígono Industrial Llevant 08150 Parets del Vallès Barcelona - España Tel. +34 93 571 93 00 Fax +34 93 571 93 01 www.solerpalau.com Ref. 9023092900...