Technical Specifications - CBE MTG LPG Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

After having turned the detector on with the front button (ref. 2), the sensor's heating procedure lasts for
about 90 seconds and is indicated by the yellow led
At the end of the heating procedure, the detector is ready to signal any alarming situation. The operating
mode is indicated by the flashing of the yellow (ref.3) (1 flash every 2 seconds).
When the gas concentration exceeds the limit established, the acoustic (buzzer with intermittent sound)
and visual (yellow led always on) alarm starts functioning.
The alarm continues to operate until the detector is turned off.
Input voltage
Absorbed current, typical
Absorbed current, alarm
Operating temperature
Humidity
Heating time
Acoustic power
Detector life
Dimensions (mm)
FUNCTIONING
(ref.3)

TECHNICAL SPECIFICATIONS

85 dB at a distance of 1 metre with external buzzer
7
.
12 Vdc
10 mA
12 mA
-10÷40 °C
30÷95%
90 sec.
10 years
60x60x20 max

Publicité

Table des Matières
loading

Table des Matières