• do not pull the power cable or appliance itself to unplug the
plug from the mains.
2) The equipment should not be used by children, adolescents
or other persons unfit to operate it (for example, while drunk).
3) Keep people away from the appliance while it is working.
4) Do not use the appliance in the rain, snow, freeze.
5) Do not obstruct ventilation and heat dispersal apertures or
slits.
6) If the appliance breaks down or malfunctions, turn it off. Do
not attempt to repair it. Contact our technical service centre.
7) Do not use the equipment if the power cable is damaged. To
replace it, contact our technical service centre only.
8) Do not clean the appliance with water jets.
9) Use suitable personal protection (gloves, masks, etc)
RECOMMENDATIONS FOR USE
Cleaning of covered and painted surfaces.
The use of pure water on glued surfaces could cause deta-
chment.
Do not use the appliance on parquet or wooden floor that are
not well sealed.
Pay the utmost attention when cleaning covered and painted
doors, parquet, aluminium panels and surfaces in general.
Before using pure water, we suggest to test a corner of the
surface, in order to avoid damage during cleaning.
Window cleaning.
Do not lead the stream of water directly on the sealed area of
the window, so not to damage the sealed corners.
USING THE EQUIPMENT
Equipment without Pump Unit.
1. Turn on water supply.
2. Open the flush valve to bleed air from system.
3. Close the flush valve when air has been cleared from
system.
4. Check pressure on gauge, minimum 30 - 45 psi (2 -3 bar).
5. Test water at the outlet, using the handheld TDS meter.
6. Use the ball valve at the pole to adjust desired amount of
pure water supplied to accessory.
Equipment with Pump Unit. (fig. 6)
With Electric Unit.
1. Turn on water supply.
2. Open the flush valve to bleed air from system.
3. Turn motor switch ON by pressing the push button.
4. Close the flush valve when air has been cleared from
system.
5. Check pressure on gauge. Normal operating pressure is
145 psi (10 bar).
6. Test pure water quality using the handheld TDS meter.
7. Use the ball valve at the pole to adjust desired amount of
pure water supplied to accessory.
With Battery Units.
3. Turn the pump control switch ON.
Note: The pump motor has a built in pressure switch that
will automatically stop the pump if the system pressure
reaches 100 psi (about 7 bar) and will restart when the
pressure drops.
Use only original attachments which offer optimum character-
istics of quality and safety. Failure to use original attachments
English
absolves the manufacturer from all liability.
Stopping the Equipment without Pump Unit:
1. Open the flush valve to allow water to flush out the RO
membrane for 1 minute.
2. Turn supply water off.
3. pure water ball valve to relieve pressure in the line. Close
valve.
4. Close flush valve after pressure has bled off.
Stopping the Equipment with Pump Unit:
1. Open the flush valve to allow water to flush out the RO
membrane for 1 minute.
2. Turn motor switch OFF by pressing the push button.
3. Turn supply water off.
4. Open pure water ball valve to relieve pressure in the line.
Close valve.
5. Close flush valve after pressure has bled off.
Turn the appliance on and off by means of the main switch only
and never by plugging in or unplugging the mains plug.
Never unplug by pulling the power cable.
IMPORTANT.
As with all technical appliances, your equipment should always
be used according to the instructions.
Only maintenance authorised in this booklet may be carried out
by the user. All other operations are prohibited.
Before carrying out maintenance of any kind, unplug the appli-
ance from the mains.
The appliance can only be disconnected from the mains by
unplugging it.
When maintenance has been completed, before reconnecting
the appliance to the mains, check that the panels have been
replaced correctly and fixed using the screws provided.
Cleaning the appliance.
Do not use direct jets of water to clean the appliance. Use a
damp cloth only.
Clean all accessories thoroughly each time they are used.
Daily maintenance:
After the last use of the day, open the drain valve for 1 minute
to flush the concentrated water from the membrane. This will
increase the life of the membrane.
PREFILTERS - DI RESIN CARTRIDGE
Every 5000 gallons (19.000 litres) Equipment without Pump
Unit;
Every 6000 gallons (22.800 litres) Equipment with Pump Unit
of feed water run through the machine as indicated by the
totallizing flow meter;
For both versions: When the TDS content of the pure water
produced exceeds 1-2% of the water supply TDS content,