Mounting material

A fully extracted awning has to withstand extreme
loads at its fastenings. Depending on the wall type
at the installation site, the correct fastening must be
selected in order to ensure a secure fixation.
The table below provides a basic recommendation
of fastenings for different wall types, but a specialist
should be consulted in order to figure out, which fas-
tening is the appropriate one. He will also be able to
inform about the wind resistance class the awning can
withstand after the installation.
WALL TYPE
Concrete
Concrete / C20-C25
Solid brick
Clay brick / MZ
Sand-lime brick / KS
Perforated brick
Clay brick / HLZ
Sand-lime brick / KSL
Aerated concrete
Gas concrete / PB2
Cavity wall
For every mounting material, the specifications of the fastening manufacturer must be ob-served, e.g. drill
sizes, distances to edges, tensioning torques, drying times etc.

Technical data

MODEL
5905357
Max. width
1950 mm
Max. extension
1550 mm
Weight fabric
280 g/m²
Weight complete
21 kg
230 V ~ 50 Hz
Power supply
Power consumption
198 W
Degree of protection
IPX4
LOCATION
FASTENING
Ceiling
e.g. TOX Anchor bolt S-Fix Pro 1 A4
Ceiling / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Anchor bolt S-Fix Pro 1 A4
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Masonry Set Wallix
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Masonry Set Wallix
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall
e.g. TOX Masonry Set Wallix
Wall / insulated
e.g. TOX Thermo Proof Plus
Wall / insulated
e.g. TOX Thermo Proof Plus
WARNING
5905358
3950 mm
3050 mm
280 g/m²
40 kg
230 V ~ 50 Hz
198 W
IPX4
WARNING
To meet the wind resistance class mentioned in
the declaration of conformity, the installed awn-
ing needs to fulfil these requirements:
The awning is installed with the recommended
type and number of brackets.
The awning is installed under consideration of
the given fastening pull-out forces.
The instructions of the fastening manufacturer
have been respected during installation.
The combination of wall type and mounting mate-
rial used at your installation site might result in a
lower wind resistance class for your awning.
6145088
5000 mm
3050 mm
280 g/m²
45 kg
230 V ~ 50 Hz
205 W
IPX4
ENGLISH
|
119