Télécharger Imprimer la page

Exquisit CM 30953 we Mode D'emploi page 28

Publicité

Les langues disponibles

Les langues disponibles

EN
15 Troubleshooting
FAULT
POSSIBLE CAUSES
Mobile air
Mains plug is not plugged into
conditioner does
the plug socket.
not start.
Display "W.F" lights up (water
tank full).
Room temperature is lower
than the set temperature.
The mobile air
Doors and/or windows are not
conditioner is not
properly closed.
operating with
the expected
effectiveness.
There are additional heat
Insufficient
sources in the room.
cooling.
Temperature is set too high.
Air inlet or outlet is blocked.
Air filter or air outlet is
Air is not blown
blocked.
out.
Operating noises. The mobile air conditioner is
not standing on a level and
stable surface.
Air filter or air outlet blocked.
Appliance makes "flowing"
noises.
Page | 28
All manuals and user guides at all-guides.com
MEASURES
Check whether the mains plug has
been plugged in correctly.
Empty the water tank.
Lower the set temperature.
Close all doors and windows, etc.
through which warm air may enter.
Remove the heat sources, if
possible.
Lower the set temperature.
Remove objects from the air
inlet/outlet. Clean the air filter and
air outlet. Observe the minimum
clearances.
See above.
Ensure that the mobile air
conditioner is standing on a level
and stable surface.
See above.
Flowing noise of the refrigerant. No
measures necessary.

Publicité

loading

Produits Connexes pour Exquisit CM 30953 we