SAFETY
MEASURES
PROTECTION ACCORDING TO EN 061008 ČL. 21
• only adults can operate the device
• device must be safely used in common surroundings according to EN 332000-4-462; EN 332000-4-42. You
must switch the gas device off under the circumstances leading: to the danger of the temporary rise of the
combustion gas or steam or during works when there is a big possibilityof rise ot the temporary fi re danger
or explosion (for example: to stick linoleum, PVC etc.).
• before you start to instal the device you must get the licence for connection to the gas feeder from the
gasworks
• device must be placed so as to stand or hang on the noncombustible surface which is on each side 10
cm larger than the device. No subjects from combustible materials can be placed directly on the device
or in distance which is shorter than safety distance (the shortestdistance is 50 cm in the direction of the
heat emission and 10 cm in other directions).- safety distances from various materials of different degree of
combustion and information about the degree of comb. of common building materials - see chart:
Chart:
Combustion degree of building materials classifi ed according to the combustion degree of materials and
products (EN 730823)
A noncombustible
B uneasily combustible
C1 hardly combustible
C2 middle combustible
C3 easily combustible
Devices must be instalated in a safe way. When instaling you must respect corresponding project, safety and
PIPE FOR GAS CONNECTION
hygienic orders according to:
It must fi rst determine if the appliance is made for the same type of gas that will be used and thus conforms
• EN 061008 fi re protection of local devices and sources of heat
to the indications on the label the type of gas to be used.
33 2000-4-482; 33 2000-4-42)
• EN 332000 (
The conversion of gas pan to another type of gas you need to check if it corresponds to the type of gas
• Gas fi ttings in the buildings - the highest operational pressure < 5 bar - operation demands
bearing, which is recommended in this guide.
• § 10 law nr. 185/2001 Sb. about waste
Connecting the appliance to the gas distribution must be towable to a steel or copper tube complying with
applicable national requirements. This must be controlled on regular basis and changed if needed. Every
Instructions for sucking off the gas products of combustion
appliance must be equipped with shut-off valve and quick shut-off valve. Quick shut-off valve must be freely
accessible and within reach of the device. After installation, is necessary to check whether there is a gas leak.
Type A devices (see the label with characteristics). Appliance of fi nish A, that is the appliance which is not
To fi nd a gas leak you can use soapy water or spray for gas leak detection.
made for being connected with the chimney or other device for sucking off the products of combustion out
of the space where the appliance is situated. These appliances must be situated in the room with suffi cient
Do not use corrosive substances!! All our appliances are carefully controlled. Gas type, pressure and of the
ventilation according to the ČSN 12 7010:1986 and ČSN 1207040:1986. It is necessary to prevent the
categories listed named on the technical information plate.
accumulation of the harmful matters in big concentration (secure the requirement of hygienic standard for
working surrounding sv. 39/78 guideline 46).
Liquid gas connection:
Pressure for liquid gas connection must be 28 or 30 mbar for propane/butane and 37 mbar for propane. It
is necessary to check the technical label ,gauge the pressure and check the parameters of the nozzle is
installed with the required parameters of the nozzle according to the manufacturer's. If the pressure is lower
than 25mbar or higher than 37 mbar, THE APPLIANCE SHALL NOT TO BE CONNECTED.
Gas Connection:
Pressure for methane connection must be 18 or 20 mbar. It is necessary to check the technical label ,gauge
the pressure and check the parameters of the nozzle is installed with the required parameters of the nozzle
according to the manufacturer's. If the gas pressure is lower than 15mbar or higher than 22,5 mbar, THE
APPLIANCE SHALL NOT TO BE CONNECTED.
5
FROM
THE
granit, sandstone, concretes,bricks, ceramic wallfacing tiles, plaster
akumine, heraklite, lihnos, itavere
leafy wood, plywood, sirkoklit, rare paper formica
fi breboards, solodure, cork boards, rubber,fl oor-coverings
wood-fi breboards, polystyrene,polyurethane, PVC
surrounding for electric devices ČSN EN 1775 Gas supplying
STANDPOINT
OF
THE
FIRE