GENERAL INSTALLATION DATA
This equipment is designed and sold for commercial use only by personnel trained and experienced
in its operation and is not sold for consumer use in and around the home nor for use directly by the
general public in food service locations.
CAUTION
The Ultra-Max™ series gas hotplate is equipped for the type of gas indicated on the nameplate
mounted on the front panel. All units are shipped from the factory for use with natural gas. The unit can
easily be converted for use with propane gas: see propane gas.
Be sure to remove all paper protection and packing material from unit prior to lighting.
Install on non-combustible countertop with 4" legs or combustible floor using a maximum
27" high stand. Clearance from combustible construction must be 9" minimum from
back wall and 7" from side walls. Clearance from non-combustible surfaces on back
and sides may be 0". For servicing, 6" is recommended from back of unit on non-
combustible walls.
The installation of the Appliance must conform to the NATIONAL FUEL GAS
CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY
RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT
CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE
When this appliance is installed with casters, it must be installed with the casters supplied, a connector
complying with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device complying with
either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining means to guard against
transmission of strain to the connector, as specified in the appliance manufacturer's instructions.
For your protection, we recommend a qualified installing agency install this
appliance. They should be familiar with gas installations and your local gas
requirements. In any case, your gas company should be called to approve the
final installation.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2
PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 PSIG.
EXHAUST CANOPY
Open hotplates create fumes, moisture, heat, and should be installed under an efficient exhaust hood
with flame proof filters. A vertical distance of not less than 48" shall be provided between the top of
the appliance and filters or any other combustible material. Exhaust installation must conform to local
codes.
AIR SUPPLY
Provisions for adequate air supply must be provided.
AIR INTAKES IN BOTTOM
CAUTION
Air for combustion enters from the front and bottom of the unit. Do not obstruct this area.
2940 Hwy 14 W, Rochester, MN 55901