Télécharger Imprimer la page

DURAVIT L-Cube LC 7386 Instructions De Montage page 4

Publicité

Safety
Intended use
The mounting instructions come as part of the Duravit
product and are aimed at people who carry out the
electrical installation for the product. You must read
through the mounting instructions carefully and they must
be available at all times.
Target readership and qualifications
The electrical installation may only be carried out by
qualified electricians.
Protection rating of Duravit products
The protection rating of Duravit products with a power
supply complies with the IP 44 standard as a minimum.
Protection class of wall lights
Protection class Connecting cable
I
H05VV-F, 3x 1.5 mm
II
H03VV-F, 2x 0.75 mm
Standards and directives
Duravit products comply with the CE marking
directives:
Icons and symbols
Symbol
Meaning
>
Action required
Disposal
• Do not dispose of the product in household
waste. Products with this symbol must be
disposed of in accordance with the WEEE
Directive through local collection points for
waste electrical equipment.
2
MAL_51240/22.04.5
Safety instructions
Danger to life
Contact with electricity may lead to an electric shock.
> Carry out the electrical installation in accordance with
the national, European and international directives and
standards.
> Observe protection zones for wet rooms in accordance
with country-specific standards, local regulations and
low voltage guidelines.
> Connect the electrics using a ground fault circuit
interrupter (GFCI) in wet rooms or other specially
equipped rooms.
> Disconnect electrical components from the power supply
before the installation.
> Check that all components are de-energised.
> Prevent the power supply from being switched on
accidentally.
Penetration of foreign bodies and water
Foreign bodies or water in equipment lead to a short circuit
2
that may cause damage to the product.
2
> Observe the protection zones for Duravit products.
Protection zones
A
B
Energy efficiency class
• This product contains an energy efficiency class D light
source.
0
6 0
A
0
6 0
1
2
0
A mirror cabinet with an IP 44 rating may protrude into zone 2.
A socket in a mirror cabinet must be mounted outside the zones.
B

Publicité

loading