Mounting Products Attached in Series
With Omega Bracket
Up to
16 cells
When using the omega bracket, never hang more than 16 cells vertically from a single mounting point.
When not using the omega bracket, never hang more than 8 cells vertically from a single mounting
point.
Vertical Mounting Stability
When mounting products attached in series, use omega brackets in the back position to create a spine. This will prevent
any motion which may damage the products.
Omega
brackets
4
QUICK REFERENCE GUIDE
Attach the
safety cable
of the first
product to the
mounting
point
Attach the
safety cables
of the following
products to the
preceding
product
Each STRIKE Array 2
product is 2 cells
Mounting
clamps
Pole or pipe
for stability
Without Omega Bracket
STRIKE Array 2 QRG Rev. 1
Up to
8 cells