PLUMBITE® PUSH ON THERMOSTATIC MIXING VALVE
A. Assembly Procedure
Before installation, the hot ("H") and cold ("C") water inlet of the mixing valve must be cleared
of scratches and imperfections.
2. To ensure proper pipe installation depth (Install depth is approximate):
• 1/2" Pipe, mark the pipe at 15/16" (24mm) from the end
• 3/4" Pipe, mark the pipe at 1-1/16" (27mm) from the end
3. While securely holding the valve, push the pipe/tubing straight in to valve. Press pipe/tubing until you
4. After installation check carefully for leaks.
5. To Remove:
collar at valve opening, carefully slide pipe/tubing the opposite direction out of the valve.
Important: Failure to comply with all aspects of these instructions may result in unsafe performance.
All installations must comply with relevant state and local authority requirements.
Check:
prior to installing the valve.
Valve MUST NOT be subjected to heat during installations as this may damage the valve internals.
Valve MUST NOT be frozen. If the valve is installed in situation where freezing is a possibility, then
(in liquid, tape or other form) as this may cause the valve to fail.
Leave a copy of these instructions with the client for future reference.
Recommend to the client that the valve be checked annually to ensure its continued function.
B. Temperature Adjustment
1. Remove the protective cap on top of the valve.
2. Back-out the nut using a hexagon wrench:
To increase the temperature, turn counter-clockwise.
To decrease the temperature, turn clockwise.
3. Allow the mixed outlet temperature to stabilize for at least 60 seconds and once again
take a temperature reading. A thermometer is needed.
4. Repeat the procedure until the desired temperature has been reached at the outlet.
5. Lightly tighten the Adjustment Locknut to prevent further spindle movement.
clips back into place.
C. Check Valve Cleaning Procedure
1. Remove the push connector from TMV body
English

Publicité

loading

Sommaire des Matières pour Jones Stephens PLUMBITE JC77468LF

  • Page 1 PLUMBITE® PUSH ON THERMOSTATIC MIXING VALVE English A. Assembly Procedure Before installation, the hot (“H”) and cold (“C”) water inlet of the mixing valve must be cleared of scratches and imperfections. 2. To ensure proper pipe installation depth (Install depth is approximate): •...
  • Page 2 VÁLVULA MEZCLADORAS TERMOSTÁTICAS DE EMPUJE PLUMBITE® Español A. Procedimiento de Ensamble Antes de la instalación, la entrada de agua caliente ("H") y fría ("C") de la válvula mezcladora debe estar despejada y veri cada. La válvula debe estar correctamente conectada a los suministros respectivos. 1.
  • Page 3 INSTANTANÉ PLUMBITE® VANNE DE MÉLANGE THERMOSTATIQUE Français A. Procédure d'assemblage Avant l'installation, l'entrée d'eau chaude (”H“) et froide (”C”) de la vanne mélangeuse doit être dégagée et identi ée. La vanne doit être correctement raccordée aux alimentations respectives. 1. Pour un ajustement parfait et étanche, utilisez un outil d'ébavurage pour éliminer les bavures. Utilisez un chi on de sable pour obtenir un bord lisse pour passer par le joint en caoutchouc du raccord sans dommage.

Ce manuel est également adapté pour:

Plumbite jc77469lf