Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

WP1 INSTALLATION INSTRUCTIONS
Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We'd like to hear your comments.
Call the Marketing Department at 888-722-1000 or email: marketing@rclighting.ca
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture.
MOUNTING
Use the Drill Template on the inside back surface of the
housing to match most standard junction boxes or lag bolt
housing to mounting surface using locations noted below.
1. Open door by loosening (4) screws. Remove reflector.
2. Prepare the housing for use by drilling out the
appropriate holes.
3. Line up the housing in desired location and mount
securely.
4. Complete the wiring to the supply wires and ground
(see wiring instructions).
5. Replace the reflector, install the lamp. Close door and
tighten the four screws.
6. To ensure weatherproof seal make sure all holes
(mounting, plugs, conduit, etc.) are sealed with
weatherproof silicone sealant.
Drill Template
All manuals and user guides at all-guides.com
LOCATION
1. Mount fixture on a wall with lens facing down as shown
2. Fixture must be level. Lamp must be in a horizontal position.
3. DO NOT mount in a way that would entrap heat.
WIRING
Do not use any supply voltage other than those specified below.
120V photocell is supplied unless specified with "/PC2" suffix,
available for CFL models only:
* No internal wiring changes needed for various voltages as the
ballast is quad tap electronic.
HID ONLY: If supply wires are located within (3) inches of bal-
last, use wire rated for at least 125°C. If supply wires are routed
and secured min (3) inches away from ballast, use wire rated for
at least 90° C.
1. Connect the appropriate voltage fixture lead to the HOT
2. Connect the "COM" fixture lead to the COMMON supply lead.
3. Fixture ground screw must be connected to supply ground.
4. All unused leads must be capped and insulated.
Lag Bolt Locations
above.
WP1SN35-100 HPS
WP1H50-70
MH
WP1F26,32,42 CFL
supply lead.
120V only
120V only
120 thru 277V*

Publicité

loading

Sommaire des Matières pour RC Lighting WP1

  • Page 1 WP1 INSTALLATION INSTRUCTIONS Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-722-1000 or email: marketing@rclighting.ca IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE.
  • Page 2 WP1 INSTALLATION INSTRUCTIONS Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-722-1000 or email: marketing@rclighting.ca...
  • Page 3 DIRECTIVES D’INSTALLATION DU WP1 Merci d’avoir acheté un luminaire de RC Lighting! Notre objectif est de concevoir des produits de la plus haute qualité, en mesure de faire correctement le travail. C’est pourquoi nous aimerions connaître vos commentaires. Communiquez avec le service du marketing au 1 888 -722-1000 ou, par courriel, à...
  • Page 4 DIRECTIVES D’INSTALLATION DU WP1 Merci d’avoir acheté un luminaire de RC Lighting! Notre objectif est de concevoir des produits de la plus haute qualité, en mesure de faire correctement le travail. C’est pourquoi nous aimerions connaître vos commentaires. Communiquez avec le service du marketing au 1 888 -722-1000 ou, par courriel, à...