1 - INTRODUCTION
The receiver ERONE 750 W Plus is a radio programmer which
can drive directly an asynchronous 230 Vac AC motor with max
power of 750 W. The operating frequency and the coding system
are different, depending upon the model.
The following table summarises the range of Erone radio
programmers, pointing out series, frequency and coding system:
SERIES
MODEL
ERONE433
SEL 2641R433P7P 433.92 MHz
ERONE433
SEL 2641F433P7P 433.92 MHz
Depending upon the modulation, the receiver operates with
different transmitters ERONE, according to the following table:
Receiver Type
Usable transmitter
SEL 2641 R433P7P S2TR2641E2/E4
SETR2641AM2
SETR2641-TM
SEL 2641 F433P7P S2TR2641F2/F4
SETR2641FM
2 - TECHNICAL SPECIFICATIONS
Type
Receiver type
Carrier frequency
Local oscillator frequency
Modulation
Input load
Intermediate frequency
Input sensitivity
Local oscillator emissions
Power voltage
Motor maximum power
Auxiliary output
Memory capacity
Operating temperature
IP grade
Weight
Overall dimensions
Type
Receiver type
Carrier frequency
Local oscillator frequency
Modulation
Input load
Intermediate frequency
Input sensitivity
Local oscillator emissions
Power voltage
Motor maximum power
Auxiliary output
Memory capacity
Operating temperature
IP grade
Weight
Overall dimensions
All manuals and user guides at all-guides.com
ENGLISH
FREQ.
CODING
Rolling code AM
Rolling code FM
SEL 2641R433-P7P
Superheterodyne
433,92 MHz
6,6128 MHz
AM/ASK
50 Ohm
10,7 MHz
-115 dBm
< -57 dBm
230 Vac
750 W
24 Vac / 200 mA
85
-20°÷+70°C
IP44
380 gr.
140 x 115 x 52 mm
SEL 2641F433-P7P
Superheterodyne
433,92 MHz
6,6128 MHz
FM/FSK
50 Ohm
10,7 MHz
-111 dBm
< -57 dBm
230 Vac
750 W
24 Vac / 200 mA
85
-20°÷+70°C
IP44
380 gr.
140 x 115 x 52 mm
3 - FUNCTIONALITY
Sequential (or cyclic):
1 Pulse opens
1 Pulse closes, stop with a timer
Mixed
1 Pulse opens, closing only with permanent contact.
Man present:
Opening and closing only with permanent contact (reduced
range). The motor time-out is selectable (from 6 to 186 sec) by
means of 5 dip - switches; it is used as security to avoid powering
MOD.
the motor for too long after the mechanical stop.
Other features:
Local and general operating selection (with multiple motor
driving); the general command is possible only for the sequential
operating mode.
For the general mode using it is necessary to use a 4 keys
transmitter of the same range.
It possible to connect an external push button or a key - contact to
complete the radiocontrol.
The memory capacity is 85 or 100 transmitters.
4 - INSTALLATION
Positioning
The local choice is very impotant for the best result of the installation.
The following conditions have to be followed:
- Fix the radioprogrammer far from the interference sources as
informatic systems, alarm systems or other radio emissions.
- The distance between 2 receivers should be greater of 1.5 mt.
Fixing
Remove the cover of the receiver; fix the box in each corner by
using the screws and the plugs supplied.
Connections
1- Connect the power supply (230 Vac) to the terminal blocks (fig.
10):
terminal 1 = PH phase
terminal 2 = N neutral
terminal 6 = earth
2 - Connect the motor to the terminal blocks (fig. 11):
terminal 3 = C common
terminal 4 = O open
terminal 5 = CL close
terminal 7 = GND ground
Connect the capacitor between terminals 4 and 5.
1
2
6
Ph
N
3
4
5
7
C O CL