Télécharger Imprimer la page
Fortin THAR-FOR3 Manuel D'installation
Masquer les pouces Voir aussi pour THAR-FOR3:

Publicité

Liens rapides

ALL
THAR-FOR3 THARNESS STAND ALONE INSTALLATION
INSTALLATION STAND ALONE HARNAIS THAR-FOR3
VEHICLE
VEHICULES
FORD
F-150
F-250
F-350
F-450
LINCOLN
MKC
MODEL: EVO-ALL
DATE:02/2019
FORTIN.CA
2019
SN: 000000 00000
MADE IN CANADA
© 2018 ALL RIGHTS RESERVED
D'UN CONTACT DE CAPOT
Parts required (Not included)
Parts required (Not included)
1x 5A Fuse
1x 1Amp Diode
1x THAR-FOR3
MANDATORY INSTALL | INSTALLATION OBLIGATOIRE
HOOD STATUS : THE HOOD PIN SWITCH MUST BE INSTALLED
* HOOD PIN
IF THE VEHICLE CAN BE REMOTE STARTED WITH THE HOOD OPEN,
SET FUNCTION A11 TO OFF.
CONTACT
STATUT DE CAPOT : LE CONTACT DE CAPOT, DOIT ÊTRE INSTALLÉ SI LE
DE CAPOT
VÉHICULE PEUT DÉMARRER À DISTANCE, LORSQUE LE CAPOT EST OUVERT,
PROGRAMMEZ LA FONCTION A11 À NON.
All manuals and user guides at all-guides.com
1 / 7
Page
ONLY COMPATIBLE WITH AUTOMATIC TRANSMISSION VEHICLES.
COMPATIBLE AVEC VÉHICULE À TRANSMISSION AUTOMATIQUE SEULEMENT.
Vehicle functions supported in this diagram (functional if equipped) | Fonctions du véhicule
PUSH
START
YEARS
ANNÉES
2015-2018
Push-to-Start
2017
Push-to-Start
2017
Push-to-Start
2017
Push-to-Start
2015-2019
Push-to-Start
QR CODE
ON THE LABEL
COMPATIBLE
MODULE
MANUFACTURED AFTER:
REQUIRED:
2019
MODULE
CODE QR
SUR 'ÉTIQUETTE
COMPATIBLE
REQUIS:
FABRIQUÉ APRÈS: 2019
Program bypass option
IF THE VEHICLE IS NOT EQUIPPED
WITH FUNCTIONAL HOOD PIN:
Programmez l'option du contournement
SI LE VÉHICULE N'EST PAS ÉQUIPÉ
FONCTIONNEL:
Program bypass option:
Programmez l'option du contournement:
REV.: 20200710
supportées dans ce diagramme (fonctionnelles si équipé)
To add the firmware version and the options, use the
FIRMWARE VERSION
FLASH LINK UPDATER or FLASH LINK MOBILE tool,
VERSION LOGICIELLE
4.01
ONLY - SEULEMENT
UNIT OPTION
OPTION UNITE
A11
OFF
NON
UNIT OPTION
OPTION UNITE
C1
Pièce(s) requise(s) (Non incluse(s))
Pièce(s) requise(s) (Non incluse(s))
1x fusible 5A
1Amp Diode
1x THAR-FOR3
Notice: the installation of safety
elements are mandatory. The hood pin
is an essential security element and
A11
OFF
must be installed.
NON
Notice: l'installation des éléments de
sécurité est obligatoire. Le contact de
capot est un élément de sécurité
essentiel et doit absolument être
installé.
Guide # 68991
ADDENDUM - SUGGESTED WIRING CONFIGURATION
ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ
sold separately.
Pour ajouter la version logicielle et les options,
utilisez l'outil FLASH LINK UPDATER
ou FLASH LINK MOBILE, vendu séparément.
DESCRIPTION
Hood trigger (Output Status).
Contact de capot (état de sortie).
DESCRIPTION
OEM Remote status (Lock/Unlock)
monitoring
Suivi des status (Verrouillage/Déverrouil-
lage) de la télécommande d'origine
THIS MODULE MUST BE INSTALLED BY A
QUALIFIED TECHNICIAN. A WRONG
CONNECTION CAN CAUSE PERMANENT
DAMAGE TO THE VEHICLE.
CE MODULE DOIT ÊTRE INSTALLÉ PAR
UN TECHNICIEN QUALIFIÉ, TOUTE
ERREUR DANS LES BRANCHEMENTS
PEUT OCCASIONNER DES DOMMAGES
PERMANENTS AU VÉHICULE.

Publicité

loading

Sommaire des Matières pour Fortin THAR-FOR3

  • Page 1 All manuals and user guides at all-guides.com 1 / 7 REV.: 20200710 Guide # 68991 Page THAR-FOR3 THARNESS STAND ALONE INSTALLATION ADDENDUM - SUGGESTED WIRING CONFIGURATION INSTALLATION STAND ALONE HARNAIS THAR-FOR3 ADDENDA - SCHÉMA DE BRANCHEMENT SUGGÉRÉ ONLY COMPATIBLE WITH AUTOMATIC TRANSMISSION VEHICLES.
  • Page 2 This guide may change without notice. See www.fortin.ca for latest version. 2 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. PARTS REQUIRED (NOT INCLUDED) | PIÈCES REQUISES (NON INCLUSES) MANDATORY | OBLIGATOIRE...
  • Page 3 This guide may change without notice. See www.fortin.ca for latest version. 3 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. DESCRIPTION | DESCRIPTION Gateway module, located at dash board driver's side, Parking Lights switch Module Passerelle réseau, situé...
  • Page 4 This guide may change without notice. See www.fortin.ca for latest version. Guide # 68991 4 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. AUTOMATIC TRANSMISSION WIRING CONNECTION | SCHÉMA DE BRANCHEMENT TRANSMISSION AUTOMATIQUE RS3 IN/OUT (+)Igni�on Can be required...
  • Page 5 This guide may change without notice. See www.fortin.ca for latest version. 5 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. PROGRAMMING PROCEDURE | PROCÉDURE DE PROGRAMMATION Press and hold Appuyez...
  • Page 6 This guide may change without notice. See www.fortin.ca for latest version. 6 / 7 Page Ce guide peut faire l’objet de changement sans préavis. Voir www.fortin.ca pour la récente version. REMOTE STARTER FUNCTIONALITY | FONCTIONNALITÉS DU DÉMARREUR À DISTANCE Start...
  • Page 7 The installation in every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly, improperly or any other way.