Télécharger Imprimer la page

KENT SelectVac 11 Manuel De L'opérateur page 10

Publicité

Les langues disponibles

Les langues disponibles

J / K - INSTALLING A DISPOSABLE PAPER
BAG
Unzip the cloth bag and pull the bag throat out of the bag's top fill
sleeve and move coil spring down on throat. Slide a new paper bag's
top fill sleeve on cloth bag's throat, wrap tightly, and move coil spring
up until it stops. Zip up cloth bag.
EMPTYING CLOTH BAG
DISCONNECT POWER CORD FROM WALL OUTLET.
The cloth bag should be emptied frequently for maximum perfor-
mance. Slide top of bag out of clamp, remove bottom by pulling back
on lever arm on bag collar. Dump contents into a waste container.
Shake vigorously several times. Reinstall bag on machine.
NOTE: It is not necessary to remove top clamp from machine.
REPLACING PAPER BAG
DISCONNECT POWER CORD FROM WALL OUTLET.
The paper bag should be changed frequently for maximum perfor-
mance. Unzip the cloth bag, and roll the coil spring off full paper bag's
sleeve. Dispose of full paper bag into a proper waste container. Slide
new paper bag's top fill sleeve on cloth bag's throat, wrap tightly, and
move coil spring up until it stops. Zip up cloth bag. (Refer to Figure
J & K)
CLEAN UP AND STORAGE
Store the machine in a cool dry place. Wind the extension cord in a
circle and hang on the cord hooks provided on the machine. Be sure
not to wind the cord tighter than necessary. Avoid prolonged
exposure of machine to freezing temperatures during storage or
transporting.
MAINTENANCE
WARNING!
BEFORE ANY SERVICING TO AVOID POSSIBLE INJURY
OR ELECTRIC SHOCK, DISCONNECT THE POWER CORD
FROM THE ELECTRICAL OUTLET.
BRUSH ROLL BELT REPLACEMENT
CAUTION!
Belt and pulley become hot during normal use.
The belt should be checked regularly. Replace belt if it is
stretching, cracking, or slipping.
Remove the bottom chrome plate by turning the two cam locks on
each side. Remove the worn belt from the drive motor pulley. Remove
the brush roll from the base, and slide off worn belt. Slip new belt
around brush roll and reinstall into machine. Install belt around drive
pulley with low side in groove. Be sure belt is installed correctly or
brush roll will turn backwards. Replace chrome cover.
NOTE: Be sure brush roll with offset belt drive is orientated correctly,
with the shorter length to the left. Arrows on brush roll end caps
indicates the top of cap and shows installation direction. Cut away any
hair or thread wound around the brush roll or the belt pulley because
the buildup could cause the belt to rotate unevenly.
BRUSH STRIP REPLACEMENT
To replace, remove the bottom chrome plate by turning the two cam
locks on each side and remove brush roll from machine. Remove nuts
and end caps. Slide out worn brush strips and replace. Reassemble
brush roll and reinstall in machine.
NOTE: Brush strips are different lengths. Arrows on brush roll end
caps indicates the top of cap and shows installation direction.
HEADLIGHT REPLACEMENT
Pry off the headlight lens. Press bulb into socket, turn and remove.
Install new bulb, and replace lens.
NOTE: Use 25 watt bulb only.
CARBON MOTOR BRUSH REPLACEMENT
Have Kent check the carbon motor brushes once a year or after 500
operating hours.
IMPORTANT !
Motor damage from failure to service the carbon brushes is not
covered under warranty.
FAN SCROLL
If your machine has a clear fan scroll attached to the underside of the
base, this may be removed and cleaned. Remove the chrome plate
and brush roll belt from pulley. Remove the two screws on either side
of the clear scroll, press the cam locks outward and lift the scroll from
the base. Dirt should clear easily, though some scraping may be
needed. Be sure the gasket is in place, reinstall by placing the rear end
between the rear wheels and seat firmly. Reinstall belt and chrome
plate.
FORM NO. 56041469 - SelectVac