Main Control Installation
The Airflow Digital Control 99-GDXPL02 is to be surface mounted onto a wall and the Airflow
Ventilation Controls 99-GBC02, 99-GBC03 and 99-GBC04 may either be installed onto a flush
mounted electrical switch box or surface mounted onto a wall. Only one master control should be installed
to a ventilation system (the face plate on this illustration may not be exactly the same as yours).
Attention
Pay special attention not to damage the contact pins when removing and detaching the face plate (Figures B and C).
1. For GDXPL02 Control, remove the operating
instructions and card from the top of the control
(Figure A).
2. Separate the face plate from the back plate by
firmly pulling apart (Figures B or C). Be careful
not to damage face plate contact pins.
3. For GDXPL02 control, place the back plate of the
control in the desired location on the wall and
pencil mark the wall with the right and left screw
holes (Figure D).
4. For GBC02, GBC03 or GBC04 controls, place the
back plate of the control in the desired location on
the wall and pencil mark the top and bottom
screw holes (Figure E or F). For mounting the
control without a Decora plate, break off top and
bottom tabs and refer to Figure F for mounting.
5. Remove the back plate from the wall and mark
the center hole for the wires in the middle of the
screw holes. Refer to Figure D, E or F for
dimensions.
6. Drill (two) 1/8 in holes for the screws and wall
anchors (Figure E, E or F). For GDXPL02 control,
drill a 1 in hole in the center (Figure D). For
GBC02, GBC03 or GBC04 controls, cut in a 3/4 in
by 1 in oval hole in the wall (Figure E or F).
7. Pull 3 wire 20 gauge (min.) 100 ft length (max.),
through the opening in the wall.
8. Connect red, green and yellow to the wiring
terminals located on the back plate (Figure D, E
or F).
9. Attach the back plate to the wall using two
supplied screws and anchors.
10.
Attached the face plate to the back plate
(Figure B or C). Note: Be careful to correctly align
the face plate to avoid damaging the face plate
contact pins.
11.
For GDXPL02 control, insert the operating
instructions card into the control (Figure A).
12. Connect the 3 wire 20 gauge (min.) 100 ft length (max.) to the terminal block located on ventilator (Red #3,
Yellow #4 and Green #5).
Operating
Instruction
Card
Figure A
Figure C
Back Plate
Face Plate
Keep top / bottom
vent openings clear
1/8 in hole for
screw and
anchor
1 in x 3/4 in
0.75"
oval hole
for wire
opening
1"
Wiring
Terminals
1/8 in hole
for screw and
anchor
Figure E
Face
Plate
Keep top / bottom
Figure B
vent openings clear
(Two) 1/8 in hole for
screws and anchors.
1 in hole for
wire opening.
Figure D
Alternate Wall Mount
1/8 in hole for
screw and
anchor
1.625"
1 in x 3/4 in
oval hole
for wire
opening
1"
1.625"
Wiring
Terminals
Break off tab
Back
Plate
Wiring
Terminals
Break off tab
Wire hole
centered
0.75"
between
screw
holes
1/8 in
hole for
screw and
anchor
Figure F
13

Publicité

loading