FUSION INSTALLATION
Mains power 230v, 2.5mm
Recommended cable outer diameter = 6-12mm
DMX Control
Recommended cable outer diameter = 4-8mm
24V input
DMX input
Maximum 54 fittings due to restrictions on cable size (2.5mm2), before new mains supply required.
Dependent on Cable size and carrying capacity. See table below.
Current Carrying capacity
O/D H07RNF approx
Fittings which can be run before new power feed required.
FUSION INSTALLATION
45°
3
All manuals and user guides at all-guides.com
gauge
2
Cables between FUSION Hubs
not supplied
Max 300M
Max 300M. Standard cable
length is 2M. Extension leads
are available.
Maximum 512 Channels.
1mm
2
15A
9.1mm
30
45°
79mm
Fusion Instructions: Helpline +44 (0) 845 862 6400.
FUSION HUB
Small FUSION hub can power 1-2 FUSIONS
Large FUSION hub can power 1-8 FUSIONS
FUSION HUB
24 or 48 LED variants
1.5mm
2.5mm
2
2
19.5A
27A
9.8mm
11.6mm
39
54
Only to be installed by a qualified electrician.
Installation must be carried out in accordance with local regulations.
Turn off mains power to the driver during installation and any
subsequent dis-connecting or re-connecting at the fitting.
Use correct polarity when wiring. If in any doubt contact the installation
helpline +44 (0) 845 862 6400.
Do not cover the luminaires or drivers with thermal insulation or vapour
barrier (see air space guidance).
acdc luminaires are designed for lighting applications and must not be
used for any other purpose.
Max 300M
INS309 Rev1