PROPANE CONVERSION INSTRUCTIONS
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
• Replace all parts and panels before operating.
natural gas. To use propane gas, the regulator and burner
WARNING
Do not operate the cooktop when using
result in serious injury.
packaged with the unit.
TOOLS REQUIRED:
(blade approximately
or 7mm
3/32" across)
To adjust your cooktop for use with propane gas, follow these
instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
CONVERTING THE PRESSURE REGULATOR
1. Use an adjustable wrench to unscrew the hex-nut cap from
the pressure regulator.
2. Turn the plastic cap 1/4 turn to disassemble.
the tabs of the plastic cap with the slots of the hex-nut cap.
Insert cap and rotate 1/4 turn to reassemble. The letters
4. Screw the hex-nut cap back onto the pressure regulator.
Rotate cap counter-
clockwise to loosen
NAT
PROPANE
CONVERTING THE COOKTOP BURNERS
Burner cap
Burner head
through this
opening
Base
Round burner
opening in the base.
NOTICE:
for future use.
from the bracket attached to
the regulator. The top surface
LR
C
LF
placement of the propane
95
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
III
JGP3036, PGP6036, CGP6036
BURNER OUTPUT RATINGS: BTU/HR
Propane Gas 10" W.C.P.
ORIFICE
BTU RATE
SIZE (mm)
MARKING
BURNER
LF
9,500
0.91
LR
12,000
1.02
C
5,000
0.66
RR
9,500
0.91
RF
15,000
1.15
D.
in their precise locations.
screwed into the gas injets.
E.
these instructions, and replace onto the regulator for
CHECK SURFACE BURNERS
Push and turn a knob to the LITE position. A clicking sound
indicates proper operation of the ignition system. When lighting
from only the one selected. Once air is purged from the supply
line, burner should light within 4 seconds. After burner lights,
rotate the knob out of the LITE position. Try each burner in
Quality of Flames
should look like (A) or (B).
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on
outer cones—
Normal for propane gas
show signs of an orange tint when well heated or signs of
RR
ADJUSTING LOW FLAME SETTING
ON COOKTOP BURNERS
RF
Low setting adjustments must be made with 2 other burners
extinguished when other burners are turned on.
A. Turn on surface burners to medium setting.
B. Turn the knob on the burner being adjusted to "LO".
shaft as shown. Turn clockwise as
far as possible while maintaining a
91L
102L
slowly turn adjustment screw
66L
91L
exists for each burner.
115L
E. Additionally, for each burner being adjusted, quickly
SPECIAL NOTE:
To convert the cooktop back to natural gas, reverse the
instructions given in making propane adjustments.
NOTICE:
the propane sticker and include your name, organization
cooktop near the regulator to alert others in the future
use natural gas.
ADDITIONAL INFORMATION
JGP3036, PGP6036, CGP6036
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas 5" W.C.P.
BTU RATE
BURNER
LF
9,500
LR
12,000
C
5,000
RR
9,500
RF
15,000
198
N
III
Round Burners
Inside shaft
Center adjustment screw
for all burners except the
Multi-Ring Burner
PROPANE CONVERSION INSTRUCTIONS
ORIFICE SIZE
(mm)
MARKING
1.33
133N
1.52
152N
0.97
97N
1.33
133N
1.73
173N
Denotes 1.98mm Orifice size opening
Denotes Natural Gas
31-2001102 Rev. 1 11-22 GEA
JGP3036, PGP6036, CGP6036

Publicité

loading

Sommaire des Matières pour Cafe JGP3036

  • Page 1 ADDITIONAL INFORMATION Normal for natural gas WARNING Do not operate the cooktop when using (B) Yellow tips on JGP3036, PGP6036, CGP6036 opening in the base. outer cones— BURNER OUTPUT RATINGS: BTU/HR Normal for propane gas NG (Natural) Gas 5” W.C.P.
  • Page 2 (A) Flammes bleu clair — Brûleur rond RENSEIGNEMENTS SUPPLÉMENTAIRES B. À l’aide d’un tournevis à douille 7 mm ou 9/32 po, retirez les JGP3036, PGP6036, CGP6036 (B) Pointes jaunes sur les PUISSANCE CALORIFIQUE DES BRÛLEURS : BTU/H AVERTISSEMENT cônes extérieurs —...
  • Page 3 Esta Abertura Calidad de las Llamas Base (A) Llamas azul suave — Quemador redondo INFORMACIÓN ADICIONAL JGP3036, PGP6036, CGP6036 (B) Puntas amarillas en ADVERTENCIA CALIFICACIONES DE POTENCIA DE LOS QUEMADORES BTU/HR AVISO: conos externos — Gas NG (Natural) 5” W.C.P. (Presión de Columna de Agua) PROMEDIO DE TAMAÑO DEL ORI-...

Ce manuel est également adapté pour:

Pgp6036Cgp6036Cgp60362ts1