Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: BFQF50, BFQF70
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
A210572219 Rev. D 12-12
All manuals and user guides at all-guides.com
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND
VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) – protected
branch circuit.
WARNING:
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY. DO NOT
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
DO NOT USE IN KITCHENS.
1 of 12

Publicité

loading

Sommaire des Matières pour Air King BFQF50

  • Page 1 All manuals and user guides at all-guides.com IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: BFQF50, BFQF70 Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: Figure 4 1 - Grill with Light Lens...
  • Page 3 All manuals and user guides at all-guides.com SECTION 5 SECTION 6 Wiring Completing the Installation CAUTION: 1. Reinstall the fan’s wire compartment cover. Rotate the blower wheel MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. by hand to ensure it spins freely. Plug the fan’s quick connect motor cord into the receptacle.
  • Page 4 Remove the light lens by squeezing at the tabs and pulling down (Figure 12). Remove lamp by gently twisting the lamp base counterclockwise while applying outward pressure. Installation is the reverse of removal. Replace with Air King model 26SBL or a compatible GU24 26 watt self ballasted lamp. Troubleshooting Guide Trouble...
  • Page 5 WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6 5S2205027 Damper Assembly 5S2299054 Fan Receptacle 5S2205004 Light Receptacle 5S1201012 Clip 5S2205025 Wire Cover 5S2205040 Blower Wheel 5S2299004 Motor - BFQF50 5S2299011 Motor - BFQF70 5S2299012 Clip 5S2205029 Motor Bracket 5S2299003 Grill Assembly 5S9205030 Light Lens 5S2205031 26 Watt Lamp 5S9999010 A210572219 Rev.
  • Page 7 All manuals and user guides at all-guides.com INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modèles: BFQF50, BFQF70 Ventilateur d’Évacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 All manuals and user guides at all-guides.com INSTRUCTIONS D’INSTALLATION 2. Fixer par pression le bâti du ventilateur dans le support (Figure 4). Le ventilateur peut être fixé par pression en position avec le collet AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION de conduit faisant face à...
  • Page 9 All manuals and user guides at all-guides.com SECTION 5 Câblage Neutre (Blanc) AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. Fil Chaud (Noir) AVERTISSEMENT : Mise à la terre TOUTES LES CONNEXIONS DOIVENT ÊTRE FAITES EN CONFORMITÉ...
  • Page 10 à la prise de la douille de lampe. Tournez le corps de la une lampe à lumière mixte de 26 watts du modèle Air King 26SBL ou d’un lampe dans le sens horaire jusqu’à ce que la lampe s’enclenche et est modèle compatible GU24.
  • Page 11 Cette garantie ne couvre pas les coûts d’expédition pour le retour des produits à Air King pour la réparation ou le remplacement. Air King payera les frais d’expédition de retour de Air King après les réparations ou le remplacement de garantie.
  • Page 12 Réceptacle du Moteur 5S2205004 Réceptacle de la Lumière 5S1201012 Clip 5S2205025 Couvercle des câbles 5S2205040 Roue de la Soufflante 5S2299004 Moteur - BFQF50 5S2299011 Moteur - BFQF70 5S2299012 Clip 5S2205029 Support du Moteur 5S2299003 Assemblée de grille 5S9205030 Lentille d’éclairage...

Ce manuel est également adapté pour:

Bfqf70