3.4. Description of the registers

On switching on the product works according to the last saved configuration (Factory Configuration if it is the first start, or if this configuration
has not been changed). Commands such as Modification TTY<n>=<M> or ATR allow you to change the content of the registers: <n> repre-
senting the number of the register and <m> the value to be assigned. This latter is either a decimal value or a hexadecimal value consistent
with the «encoding» column of the tables below.
Examples:
• ATS300=6 assigns the decimal value 6 in register 300
• ATS302=2 assigns the hexadecimal value 0x02 in register 302
It is imperative to save the parameters with the command AT&W before exiting the Command mode otherwise all changes will be lost.
EN
IMPORTANT: The registers that are not documented (that can appear in the list following the AT/S command) in the paragraphs that follow are
reserved and must not be changed.

3.4.1 Function registers

The list of registers below allows you to change the behaviour of the product application.
Register
Description
300
Transmission period of the Keep Alive
frame
301
Transmission period of data sensors
302
Configuration of the internal sensor
303
Configuring the event behaviour of the
internal sensor
304
Configuration of the external sensor
305
Configuring the event behaviour of the
external sensor
306
Global operation
Coding
Details
Decimal
Default: 144
Min/max: 1 à 255
Unit:
x 10min if S306=1
x 20s if S306=2
Decimal
Default: 1
Min/max: 0 à 255
Unit:
x 10min if S306=1
x 20s if S306=2
The value 0 means no periodic sending, therefore event operation
Hexadecimal Default: 0x00
Bits 0 to 3: Reserved
Bits 4 to 7: Identifier (free to use)
Hexadecimal Default 0x03
Bits 0 to 1: Threshold triggering
• 0 = None
• 1 = Low only
• 2 = High only
• 3 = Low and High
Bits 2 to 7: Reserved
Hexadecimal See details of register 302
Hexadecimal See details of register 303
Decimal
Default: 0
Allows the product to be switched into one of the following modes:
• 0: PARK mode
• 1: Production mode
• 2: TEST mode
• 3: REPLI mode