Télécharger Imprimer la page

CASTELLI MATTIA 12 C Manuel D'installation Et D'entretien page 121

Publicité

Les langues disponibles

Les langues disponibles

2
developed in compliance with the UNI 10683- EN
1856-1-2- EN 1857- EN 1443- EN 13384-1-3- EN
12391-1 standards both regarding the dimensions
and the materials used in its construction.
DILAPIDATED chimneys, made with unsuitable
materials (fi brocement, galvanized steel, etc...
with rough and porous internal surfaces) are not
allowed and compromise the proper operation of
the stove.
Flue gases can be released through a traditional
chimney
(Fig.
maintenance of the chimney is guaranteed;
For chimneys with a larger section, it is necessary
to "intubate" the chimney with steel piping (of
a diameter based on the path), which must be
properly insulated (fi g. 5.9).
Check that the connection to the chimney in
masonry is properly sealed.
If the pipes pass through roofs or wooden walls,
you should use special certifi ed transition kits,
commercially available.
5.5.2 Instructions to create the top exhaust
NOT VALID FOR FRENCH MARKET
1. Connect the protection in
the relative slots in the bot-
tom side.
1
3
1) Vermiculite and/or mineral wool.
2) Steel piping.
3) Closing panel.
Fig. 5.9
5.8)
provided
the
proper
2. Detail of positioning.
Extraction
primary air
Flue Gas
Outlet
3. Free the plug with the
dedicated screw.
10/2021 - EN
A) Windproof chimney stack
B) Seal
C) Inspection
Flue Gas Outlet
Ducted
Outlet
Ducted
Outlet
4. Detail of properly installed
protection.
Fig. 5.8
13

Publicité

loading

Produits Connexes pour CASTELLI MATTIA 12 C

Ce manuel est également adapté pour: