This unit is a highly efficient monobloc air/water heat pump for outdoor installation. The
technical structure as well as all components are designed for a long service life even
with harsh weather conditions.
The unit is intended for space heating in detached and multi-family houses as well as
in small industrial businesses. Furthermore. it can be optionally used for space
cooling and DHW heating. Application range: -25 up to +45 °C outside temperature.
After instructed by qualified personnel and with due regard to these installation and
operating instructions. the user can operate it safely. Any other use or one which goes
beyond the intended use specified in this manual shall be deemed as improper.
• For a safe operation of the appliance. the user must have read and understood this
manual before commissioning.
• Keep this manual in a place that is accessible at all times.
• If you sell the appliance or pass it on to somebody else. this manual must also be
handed over along with the unit.
• Please observe all safety instructions! Non-observance can endanger you and others.
• The appliance must not be operated by children or by people with limited cognitive
abilities.
• Always switch off the external main switch before any cleaning work.
• Do not modify any safety or control devices.
• Do not pull. remove or twist any power cables exiting the unit.
• Do not insert any objects through the grid and into the fan.
• Repairs may only be carried out by qualified personnel while adhering to all
country-specific regulations.
• Have qualified personnel perform inspections and maintenances regularly.
• While being connected or during maintenance. live components must never be
accessible unattended.
• During and immediately after operation some components (e.g. pipes) may be
dangerously hot or cold. Do not touch such parts or. if necessary. only with suitable
protective equipment.
• We do not bear any liability for damages caused by failure to observe these
operating instructions.
• Works on the refrigerant circuit may only be carried out by qualified personnel
and are prohibited without a valid certificate of competence.
• Ready-to-connect heat pump incl. refrigerant
• Controller with pre-assembled cable. cable length 20 m*
• Temperature sensor for DHW (domestic hot water). cable length 20 m*
• Temperature sensor T6. cable length 20 m*
• Water drain valve*
• Installation and operating instructions/manual
Always keep packaging material out of the reach of children!
*Inside the unit. behind the front panel. For opening the front panel. see chapter 3.4 on page 62 of this manual.
Multi-functional DC inverter air/water heat pump
53
General
Intended use
General safety regulations
Scope of delivery
1
1.1
1.2
1.3
GB

Publicité

loading

Ce manuel est également adapté pour:

650 001 331650 001 332650 001 333