Télécharger Imprimer la page
Empire Comfort Systems ROK-1 Instructions Pour L'installation
Empire Comfort Systems ROK-1 Instructions Pour L'installation

Empire Comfort Systems ROK-1 Instructions Pour L'installation

Modèles pour la sortie arrière, radiateurs muraux avec évent

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installing Optional Rear Outlet
Rear outlet kit, 10" boot assembly with register, ROK-1 for warm
air discharge into an adjoining room.
Attention: Before furnace is attached to the wall, the wall opening
for the rear outlet must be cut, in addition to removal of the outer
and inner casing knockouts on furnace.
1. The wall opening measurements for the rear outlet are the fol-
lowing.
A. From floor to bottom of wall opening is 10 11/16".
B. From bottom of wall opening to top of wall opening is 8
1/2".
C. Wall opening width is 12 1/8".
2. Scribe a line between the four dimples on the outer casing back
to form a square. Drill a pilot hole within the scribed square
on the outer casing back. Remove the sheet metal within the
scribed square with a tin snips or comparable tool.
3. Remove the (4) #8 x 3/8" screws that attach the inner casing
close off plate to the inner casing.
4. Insert the privacy shield through the outer casing back and the
R-3159
Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529
7/01
All manuals and user guides at all-guides.com
INSTALLATION INSTRUCTIONS
REAR OUTLET, KIT NUMBER ROK-1
FAW-40SPP AND FAW-40IP VENTED WALL FURNACES
5. Attach furnace to wall (refer to Installation Instructions and
6. Align clearance holes on 8" x 12" boot with screw holes on
7. Attach 8" x 12" boot to outer casing back with (6) #8 x 3/8"
8. Align clearance holes on 6" x 10" duct with screw holes on
9. Attach 6" x 10" duct to inner casing back with (4) #8 x 3/8"
10. Insert rear register into 8" x 12" boot. Attach rear register to
11. Installation of ROK-1 is completed.
R-3159
MODELS
inner casing back. The privacy shield will be in front of the
inner casing back and behind the combustion chamber tubes.
Align clearance holes on privacy shield with screw holes on
inner casing back. Attach privacy shield to inner casing back
with (2) #8 x 3/8" screws provided. Attention: The (2) #8 x
3/8" screws must be inserted from the front of the furnace.
Owner's Manual).
outer casing back and mark boot to be flush with wall surface.
Remove boot and cut to proper length.
screws provided.
inner casing back and mark duct to be 2 1/4" shorter than 8" x
12" boot. Remove duct and cut to proper length.
screws removed in Step 3, 2 on top and 2 on bottom.
wall with (2) #10 x 1" screws provided.
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems ROK-1

  • Page 1 Installing Optional Rear Outlet inner casing back. The privacy shield will be in front of the Rear outlet kit, 10" boot assembly with register, ROK-1 for warm inner casing back and behind the combustion chamber tubes. air discharge into an adjoining room.
  • Page 2 INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION Installing Optional Rear Outlet 4. Attach furnace to wall (Refer to Installation Instructions and Rear outlet kit, 10" boot assembly with register, ROK-1 for warm Owner's Manual). air discharge into an adjoining room.
  • Page 3 L’assemblage de sortie arrière, l’assemblage du trémie de 10" (254mm) rière avec (2) vis #8 x 3/8" (9mm). Les vis sont fournies. Attention: avec registre, le ROK-1 sert à l’évacuation d’air chaud dans une pièce Les (2) vis #8 x 3/8" (9mm) doivent être insérées à partir de l’avant du radiateur.
  • Page 4 L’assemblage de sortie arrière, l’assemblage du trémie de 10" (254mm) 4. Fixer le radiateur au mur (Référez-vous aux Instructions pour avec registre, le ROK-1 sert à l’évacuation d’air chaud dans une pièce l’Installation et Manuel du Propriétaire). avoisinante. Aligner les trous libres du trémie de 8" x 12" (203mm x 305mm) avec les trous de vis de la paroi extérieure arrière et marquer...

Ce manuel est également adapté pour:

Faw-40sppFaw-40ip