Télécharger Imprimer la page

Atlantic WWCS2 Manuel Du Produit page 6

Publicité

Les langues disponibles

Les langues disponibles

TRANSFORMERS - TRANS88 / TRANS150
Installation
Strip and connect the wires to the outlet power terminals on the back
of the transformer. Loosen the screws on the outlet power
terminals and slide the wire under the screw plate.
Tighten the screws to secure the wire.
Mount the Transformer in the desired location.
The Transformer is weather-resistant and must
be mounted above the ground on a wall or post.
Ensure that the power cord is within reach of a
properly grounded Ground Fault Circuit
Interrupter (GFCI) equipped outlet.
After all connections to low voltage lights have been completed,
plug the input power cord into the 120 volt GFCI outlet to complete installation.
Operation
The TRANS88 and TRANS150
have a control panel featuring
a rotary timer control switch,
photocell and circuit
breaker/reset button.
The circuit breaker will turn off
power to the lighting system in
case of overload/power surge.
If the circuit is tripped, inspect/repair
the lighting system and depress the reset
button to restore power. The photocell
automatically turns the transformer on
when it begins to get dark outside. The
photocell does not need to be in direct sunlight; however it must have access to indirect
sunlight to operate effectively.
The timer switch provides several modes of operation. You can choose OFF, ON, AUTO, 4H, 6H,
or 8H.
OFF: Output power is off / system is off
ON: Output power is on / system is on at all times
AUTO: Photo cell will turn the output power on at
dusk and off at dawn
4H: Photo cell will turn the output power on at
dusk and it will turn off after 4 hours
6H: Photo cell will turn the output power on at
dusk and it will turn off after 6 hours
8H: Photo cell will turn the output power on at
dusk and it will turn off after 8 hours
6
Outlet Power
Terminals
Circuit Breaker / Reset Button
Photocell Sensor
Timer Control
Input Power Cord
6H
4H
8H
AUTO
ON
OFF

Publicité

loading