Circuit diagram
WARNING!
1.0 to 10.0 kW (type A)
AHFOR-BI-A-...
AHFOR-B-A-...
12.0 to 18.0 kW (type E)
AHFOR-BI-E-...
AHFOR-B-E-...
ASKOHEAT-
_180_1-18_en
FO
Flange heater Ø 180 mm
All power supply circuits must have been switched off before accessing
the connec on terminals .
O p e r a t i n g v o l t a g e :
- L/N
» Insert jumper L1-L2-L3 for 230 V~!
- L1/L2/L3
» The neutral conductor (neutral point) may not be
connected for 400 V~!
» The regula%ons of the local electrical power u%li-
%es must be complied with!
O p e r a t i n g v o l t a g e :
- L1/L2/L3
» The regula%ons of the local electrical power u%li-
%es must be complied with!
O p e r a t i n g v o l t a g e :
- L/N
- L1/L2/L3
» The power contactors must be fiBed by the
customer!
» The regula%ons of the local electrical power u%li-
%es must be complied with!
MVGASV_160101_en_V4
230 V ~ (1.0 - 3.0 kW)
400 V 3~ (1.0 - 3.0 kW)
400 V 3~ (4.0 - 10.0 kW)
230 V ~ (control voltage)
400 V 3~ (power)
www.askoma.com