Commissioning
1
Mounting
 Base mounting
 Secure the Advanced Tower Lamp with four M5 screws (2 N•m).
 Flat mounting
 Secure the Advanced Tower Lamp with two M5 screws (2 N•m).
 Base mounting, hinged
 15° angle increments
 Angle adjustment screw
 The angle of the module can be adjusted in intervals of 15 degrees in a range of
180 degrees, thereby enabling vertical, horizontal and inclined installation. Fas-
ten at the desired angle with the help of the built-in screw.
2
Electrical connection
 Pin assignment
 Press
 Press to insert the wire.
Cable pin assignment
Pin assignment
Light color: white / buzzer
Light color: green
Light color: yellow/orange
GND
Light color: blue
Light color: red
Multicolor
Switch position for flashing
RED
GREEN
BLUE
PINK
YELLOW
TURQUOIS
WHITE
9
Conductor
Pin
color
White
1
Green
2
Yellow
3
Black
4
Blue
5
Red
6
7
8
M12 connector pin assignment
Pin assignment
Light color: white / buzzer
n.c.
Light color: green
Light color: yellow/orange
GND
n.c.
Light color: blue
Light color: red
1
2
1
0
0
1
0
0
1
0
1
1
0
1
1
1
Conductor
color
White
Brown
Green
Yellow
Gray
Pink
Blue
Red
3
0
0
1
1
0
1
1

Publicité