ELECTRIC LIFT TABLE
PROBLEM
Platform will not raise
(pump running).
Platform will not
remain elevated.
Platform will not
lower.
Platform lowers too
slowly.
Cylinder(s) leaking.
Pump leaking.
Bouncing platform.
Misaligned lifting lug
holes.
If the troubleshooting section does not resolve your problem, contact Uline Customer Service at 1-800-295-5510.
PAGE 1 OF 5
1-800-295-5510
uline.com
TROUBLESHOOTING
CAUSES
No hydraulic fluid in reservoir.
Load too heavy (relief valve operating).
Lowering valve held open.
Lower valve held open.
Pump check valve not seated.
Platform or scissor lift obstruction.
Lowering valve not opening.
Obstruction in flow limiting valve.
Lowering valve not opening
completely.
Obstruction in flow limiting valve(s).
Cylinder seals worn or damaged.
Valves, fitting or hoses loose.
Reservoir overfilled with oil.
Hose or fitting loose.
Air in hydraulic circuit.
Top may have shifted in transit.
Para Español, vea páginas 2-3.
Pour le français, consulter les pages 4-5.
RECOMMENDATIONS
Fill reservoir.
Reduce load.
Check lower control for malfunction.
Clean and/or replace lowering
solenoid.
Check lower control for malfunction.
Clean and/or replace lowering
solenoid.
Clean/repair/replace valve.
Flush outlet check.
Remove obstruction or reposition lift.
Clean and/or replace lowering
solenoid.
Flush flow limiting valves.
Clean and/or replace lowering
solenoid.
Flush flow limiting valve(s).
Repack cylinder(s).
Tighten valves, fittings or hoses.
Drain excess fluid.
Tighten fittings or hoses.
Raise and lower platform several times
to remove air and check fluid level.
Use rubber mallet to realign top with
lifting lug holes.
0423 TH-10646

Publicité

loading

Sommaire des Matières pour Uline H-10646

  • Page 1 Misaligned lifting lug Top may have shifted in transit. Use rubber mallet to realign top with holes. lifting lug holes. If the troubleshooting section does not resolve your problem, contact Uline Customer Service at 1-800-295-5510. PAGE 1 OF 5 0423 TH-10646...
  • Page 2 H-10646, H-10647 800-295-5510 uline.mx MESA DE ELEVACIÓN ELÉCTRICA SOLUCIÓN DE PROBLEMAS PROBLEMA CAUSAS RECOMENDACIONES La plataforma no se No hay fluido hidráulico en el Llene el depósito. levanta (bomba en depósito. funcionamiento). Carga demasiado pesada (válvula de Reduzca la carga.
  • Page 3 Si no se resuelve el problema utilizando la sección de solución de problemas, comuníquese a Servicio a Clientes de Uline al 800-295-5510. 800-295-5510 uline.mx PAGE 3 OF 5 0423 TH-10646...
  • Page 4 H-10646, H-10647 1-800-295-5510 uline.ca TABLE ÉLÉVATRICE ÉLECTRIQUE DÉPANNAGE PROBLÈMES CAUSES RECOMMANDATIONS La plateforme ne Pas de liquide hydraulique dans le Remplissez le réservoir. s'élève pas réservoir. (pompe en marche). Diminuez la charge. Charge trop lourde (soupape de décharge actionnée). Soupape d'abaissement maintenue Vérifiez si la commande d'abaissement est...
  • Page 5 Si la section de dépannage ne peut résoudre le problème, contactez le service à la clientèle de Uline au 1 800 295-5510. 1-800-295-5510 uline.ca PAGE 5 OF 5...

Ce manuel est également adapté pour:

H-10647