NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE
FOLLOWING POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE
WARANTY OF THE PRODUCT
Before any opera on on the float remember to disconnect the power supply from the main
Ÿ
power.
Check that the maximum motor power does not exceed the float's electrical values.
Ÿ
In case of cable damage by the final user or installer, the float must be replaced.
Ÿ
Do not make any joint on the cable of the float switch, as immersion of such joints could cause
Ÿ
short circuits or electrical shocks.
TECHNICAL FEATURES:
Protec on Grade: IP 68
Ÿ
Features of automa c ac on: 1B (micro-disconnec ons in opera on)
Ÿ
Pollu on Degree: 2
Ÿ
TERMINAL CONNECTIONS:
The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of
protec on shall null and void the warrany in the event the float breaks.
Mod.01: single func on - only emptying or only filling (Fig.1). The grounding wire is always
Ÿ
yellow and green.
Mod.02 – Mod.03 double func on (the fi er can choose the emptying Fig.2 or filling Fig.3 when
Ÿ
installing):
Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and
Ÿ
closes when the float is up. Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit closes when float is down and
Ÿ
opens when the float is up. Note: the brown wire must be insulated.
Fig.1
L
Brown
Blue/Grey
N
Yellow/Green
M
All manuals and user guides at all-guides.com
ENGLISH
Fig.2 emptying
Black
L
Brown
N
Blue/Grey
M
Ac va on angle:
Fig.3 filling
Black
L
Blue/Grey
N
Brown
M
45°